1  IMPORTANT FACTS: 

READ BEFORE COMMENCING PUMP INSTALLATION

A. 

Water temperature

The water entering the pump must be controlled as follows:
1.11  The maximum allowable water temperature is 35 

o

C.

1.12  The minimum allowable water temperature is 4 

o

C.

B. 

Pipework - General

1.13 

Secure pipework:

 Ensure pipework to and from pump is independently  

 

 

supported & clipped to prevent forces being transferred to inlet and outlet  

 

 

branches of pump.

1.14 

Flux:

 Solder joints must be completed and flux residues removed prior to pump  

 installation 

(flux damage will void any warranty)

.

1.15 

Pipework design:

 Care should be taken in the design of pipework runs to  

 

 

minimize the risk of air locks e.g. use drawn bends rather than 90

o

 bends.

1.16

  DO NOT

 introduce solder flux to flexible hoses, pump or pump parts.

1.17

  DO NOT

 allow contact with oil or cellulose based paints, paint thinners or  

 

strippers, acid based descalents or aggressive cleaning agents.

1.18 

Water flow:

  An un-assisted flow rate of at least 0.6 l/min is required    

 

 

through the outlets to be pumped in order to make this pump work.

C. 

Plumbing Installation Regulations

1.19  The plumbing installation must comply with the current water and building  

 

 regulations.

Содержание mainsboost MBF 60-1-15

Страница 1: ...oklet with the owner as it contains important guarantee maintenance and safety information MBF 60 1 15 Pt No 46631 MBF 80 1 15 Pt No 46634 Read this manual carefully before commencing installation Thi...

Страница 2: ...and operating instructions in this booklet must be followed z z The pump must not be used for any other application without the written consent of Stuart Turner Limited z z The pump must be installed...

Страница 3: ...le free service Failure to install the unit in accordance with the installation instructions will lead to invalidation of the warranty STORAGE If this product is not to be installed immediately on rec...

Страница 4: ...uge 2 Flexible hoses 2 Valve strainer check valve combined 1 Pressure regulating valve 1 Adapter G to G 1 A B C D E F Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prio...

Страница 5: ...emoved prior to pump installation flux damage will void any warranty 1 15 Pipework design Care should be taken in the design of pipework runs to minimize the risk of air locks e g use drawn bends rath...

Страница 6: ...casing can become very hot under normal operating conditions Care must be taken to ensure it cannot be touched during operation 2 15 Water retention Site the pump in a location where in the unlikely e...

Страница 7: ...check valve must be fitted c It is advisable to fit a bypass pipe and isolating valves This will allow removal of the pump for maintenance and servicing and ensure the water supply into the property...

Страница 8: ...onnection unit should be mounted in an easily accessible position and should be labelled if confusion is possible to allow easy identification of the flomate isolating switch 3 17 Earthing This applia...

Страница 9: ...factory pattern is always maintained If the supply cord is to be changed or is damaged it must be replaced with a special cord assembly available from Stuart Turner or one of their approved repairers...

Страница 10: ...nce to re fill the vessel ready for next use 4 13 For Further Technical Support Phone the Stuart Turner PumpAssist team on 44 0 800 31 969 80 Our staff are trained to help and advise you over the phon...

Страница 11: ...30 litre 40 litre Dry run protection Materials Pump body Brass Impeller Brass Performance Maximum head closed valve 3 2 bar Maximum flow 16 l min Maximum working pressure 450 kPa 4 5 bar Maximum ambie...

Страница 12: ...ts Pump runs on when all terminal outlets are closed Leak in system Check tap washers w c valve washers pipe joints Reed clamp out of position Ensure reed clamp is fitted correctly in location groove...

Страница 13: ...ng this extent of movement If this does not happen this indicates a possible fault with the reed switch or the P C B which is located within the terminal box These should be checked electrically Consu...

Страница 14: ...ternal parts of the terminal box z z Briefly reconnect the mains power supply to the pump the power on light should illuminate if the pump has been correctly wired z z Isolate the mains electrical pow...

Страница 15: ...wear and tear and defects which have a negligible effect on the value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior...

Страница 16: ...roduct launches and access to any special offers or promotions Following initial registration Stuart Turner offers a professional training programme enabling you to achieve Approved Installer status a...

Отзывы: