![Stuart Turner 41712 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/stuart-turner/41712/41712_installation-operation-and-maintenance-instructions-manual_1386355028.webp)
- 28 -
9 TECHNICAL SPECIFICATION
MJ3 VM
41712
MJ3 HM
41729
General
Warranty
5 years (fi ULK 2 years)
WRAS approval
1501305
Approvals
WRAS, CE
Typical noise
From 50 dB(A)
Features
Bypass
22 mm
Mounting
Vertical vessel
Horizontal vessel
Pump type
Peripheral
Flexible hoses
2
Dry run protection
ü
ü
Materials
Pump body
Brass
Impeller
Brass
Mechanical seal
EPDM / PTFE / Al. Oxide
Performance
Maximum head - closed valve
4.3 bar (43 metres)
Maximum working pressure*
600 kPa (6 bar)
Maximum ambient air temperature
40
o
C
Min / Max operating temperature
Min 4
o
C / Max 35
o
C
Connections
Pump connections
G ¾ male
Flexible hoses
Connections
22 mm push-in x 22 mm push-in x 240 mm long
Motor
Type
Induction (auto-reset thermal trip)
Duty rating
Continuous (S1)
Electrical
Power supply (Vac/Ph/Hz)
230 V a.c. / 1 / 50 Hz
Power consumption - P1
398 Watts
Current - full load
1.8 Amps
Fuse rating
3 Amps
Power cable length
1.5 metres (pre-wired)
Physical
Enclosure protection
IPX4
Pump Length**
200 mm
Pump Width*
203 mm
Pump Height - excluding hoses and bracket**
216 mm
Weight - including fittings
8.0 Kg
8.1 Kg
*NOTE:
The maximum pressure that can be applied to the system under any
installation conditions.
** NOTE:
See overleaf for overall system dimensions when the MJ3 pump is
fitted to a vertical or horizontal Mainsboost pressure vessel.
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
9.11
Noise:
The equivalent continuous A-weighted sound pressure level at a
distance of 1 metre from the pump does not exceed 70 dB(A).