![Stuart Turner 41712 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/stuart-turner/41712/41712_installation-operation-and-maintenance-instructions-manual_1386355016.webp)
- 16 -
g)
Ensure the floor is sufficiently strong enough to take the total weight of the
unit when full of water (see Technical Specification section). Take care when
manoeuvring the unit so as not to damage it.
NOTE:
Do not
forget if a water softener is to be installed this has to
be included in this pipe run, and additional space must be allocated
for this.
Do not
fit smaller pipework than the upstream line-in kit accepts as
this will impair performance.
h)
Fix the Mainsboost vessel securely to the floor using appropriately selected
and sized fixings.
Pump manifold assembly:
Vertical variant: Remove the pump manifold assembly from the packaging and
connect it to the pump assembly using the two fibre washers provided.
Fig. 14
Vertical
Fig. 15
Inlet
Manifold assembly
Outlet
Sealing
washers
Bypass valve and