WARNING:
4400-Lb. Capacity E
xrtra-Long Pallet Jack
OWNER'S MANUAL
• To avoid serious bodily injury or death, and/or property damage, do not exceed the rated
load capacity.
• When not in use, do not allow heavy loads to remain on the fork for an extended period of
time. Always lower the fork completely when not in use.
Adjusting the Control Handle - 3 Positions
On the drawbar of this pallet jack, you can find the control handle (117N) which allows for three
positions (Fig. 3):
LOWER - To lower the load, pull up on the control lever.
NEUTRAL - Place the control lever in this position while pulling the pallet jack or load.
LIFT
- To raise the load, push down on the control lever and pump the handle to raisethe
load.
Fig. 3
Note:
These three positions have been set at the factory to work as soon as the handle is
attached. However, if the forks do not raise or lower as expected, adjust the control positions
using the following instructions:
1. The adjusting screw (D121 N) (Fig.2) is designed to adjust the 3 control positions. Use a
wrench and a slotted screw driver to loosen the nut and turn the adjusting screw clockwise,
or counter-clockwise, in order to leave 4-5 threads out after the nut is secured on the lever
plate (D120N). Check to see if the pallet jack works correctly in the 3 control positions. If
more adjustments are necessary, proceed to the following steps.
2. Place the control handle in the NEUTRAL position. If the fork frame does not rise when you
pump the pallet jack, skip to step 5. If the fork frame does rise when you pump the pallet
jack, turn the adjusting screw CLOCKWISE until the fork frame does not rise.
3. Keep the control handle in the NEUTRAL position. If the fork frame does not move when the
handle is pumped, skip to step 4 without any adjustment. If the fork frame lowers, turn the
adjusting screw COUNTER-CLOCKWISE until the fork frame does not lower.
4. Pull the control handle upward to the LOWER position. If the fork frame lowers, skip to step5
without any adjustment. If the fork frame does not lower, turn the adjusting screw
CLOCKWISE again until the fork frame lowers.
5. Push the control handle down to the
LIFT
position. If the fork frame (D214N) elevates when
you pump the pallet jack, go back to check steps 1 to 3 until the pallet jack can work well in
all 3 control positions. If the fork frame does not elevate, turn the adjusting screw
COUNTER-CLOCKWISE again until theforkframeelevates. Repeat steps 1 thru 3 until the
pallet jack works in all 3 control positions.