XG3/020
TROUBLE CHART
NORMAL OPERATION
WHEN THE SWITCH in the main AC supply line to the xenon power supply is in the ON
position, and the 30 A. circuit breaker on the switching power supply is ON, the POWER lights on the xenon
power supply and the lamphouse instrument panel will glow. The lamphouse blowers will start. The blowers
in the power supply will operate.
OPERATION OF THE LAMPHOUSE BLOWERS will close the (2) air flow interlock switches,
and if the lamphouse door is closed and correctly secured, the control circuit to the LAMP switch will be
completed.
THE MODE SWITCH, located on the lamphouse instrument panel, should be in the MAN.
(Manual) position.
WHEN THE
LAMP
SWITCH is placed in the ON position, the AC control circuit (5 & 6) in
the lamphouse will energize the power supply circuitry providing DC current to the igniter and bulb.
THERE WILL BE a distinctly audible high voltage arc ping at the igniter arc gap and across
the bulb electrodes. The bulb should ignite immediately after one or two of these high voltage pulses, and the
lamp current will adjust to the output setting of the xenon power supply. Multiple ignition pulses prior to bulb
ignition normally indicate a low DC output setting. See xenon power supply manual. A warm or aged xenon
bulb might also require multiple strikes.
TROUBLE SHOOTING
IF THE XENON BULB does not ignite, observe the following operational sequences for assis-
tance in locating and isolating the trouble area.
WHEN THE FAN(S) and the indicator light on the power supply are on, the circuit in the
power supply is trouble-free up to the terminal block in the power supply.
AT THIS TIME, the lamphouse blowers should operate. If this does not occur, the trouble is
in the door interlock switch, one of the blower motors, a loose connection, a broken #2, #4, #7 or #8 lead, or a
blown F1 seal blower fuse. Check the 1.5 A. fuse in the in-line fuseholder. CAUTION: In order to prevent bulb
ignition when checking the AC control circuit in the lamphouse, remove lead #10 from the igniter terminal strip.
CHECK AT THIS TIME for
115 V.AC Control Voltage
at the access door interlock switch
(wires 2 & 4), and 220 V.AC at the blower terminals (7 & 8). The door interlock switch must be manually
actuated to energize the exhuast and lens blowers. Replace #10 lead before proceeding.
THE VANES on the air flow switches should raise. With the MODE switch in the MAN.
position and the LAMP switch in the ON position, the running time meter should start and indicate elapsed
time. If this meter does not operate, check for continuity at the MODE and LAMP switches.
A DEFECTIVE RUNNING TIME METER will
not
prevent bulb ignition.
Содержание XENON GLADIATOR II
Страница 2: ......
Страница 17: ...XG3 015 ...
Страница 27: ...FIGURE 1 XG3 025 1 2 3 4 5 6 7 8 9 10 11 12 ...
Страница 29: ...FIGURE 2 XG3 027 1 2 3 4 5 6 7 8 9 10 11 12 ...
Страница 31: ...FIGURE 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 XG3 029 ...
Страница 34: ...FIGURE 4 XG3 032 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ...
Страница 36: ...1 2 3 4 5 6 7 8 9 10 FIGURE 5 IGNITER ASSEMBLY XG3 034 ...
Страница 39: ...FIGURE 6 XG3 037 ...
Страница 41: ...FIGURE 7 XG3 039 ...
Страница 43: ...FIGURE 8 XG3 041 ...
Страница 46: ...58 59 FIGURE 9 Item 58 Bracket mounts to back surface of Item 31 XG3 044 ...
Страница 50: ...FIGURE 10 47 XG3 048 ...
Страница 53: ......
Страница 54: ......
Страница 55: ......