T R O U B L E S H O O T I N G

SYSTEM ISSUE

LIKELY CAUSE

POSSIBLE SOLUTION

No Hot Water Is Supplied When 

The Tap Is Turned On.

Inlet flow rate is less than 

0.4L/Min

Increase the inlet flow rate

There is no power supply

Please call an electrician to 

inspect your installation

Outlet Temperature Is Too Hot

Flow rate is too low

Increase the flow rate at the 

unit

Outlet Temperature Is Too Cold

Flow rate is too high

Reduce the flow rate at the tap

Flow Rate At The Tap Is Low

Filter washer clogged

Please clean the filter washer

Water Flow At The Tap Is 

Uneven Or Spraying

Sprinkler at the tap is blocked 

or impeeded

Remove limescale from 

sprinkler and clean.

Your 

Strom Limited

 water heater is guaranteed for a period of 12 months from the date of purchase. The 

unit is only guaranteed if the water heater has been installed and maintained in accordance with these 
instructions. Full guarantee information can be found at: 

www.stromltd.com/guarantee

The guarantee specifically excludes:
• 

Corrosion by incorrect maintenance of the water heater, or incorrect installation.

• 

Limscale build up.

• 

Consequential losses, including labour charges and damages to fittings.

• 

Any water heater that has not been maintained and installed in accordance with this manual.

• 

Products not installed by a qualified electrician in accordance with this manual.

G U A R A N T E E

For technical support regarding your water heating product please 
ensure that you have:

• 

GOT YOUR PRODUCT SERIAL NUMBER.

• 

HAVE SET THE CORRECT FLOW RATE FOR YOUR UNIT.

• 

HAVE YOUR ELECTRICAL INSTALLATION CERTIFICATE TO HAND.

T E C H N I C A L   S U P P O R T

CALL US ON:

MON-FRI, 8:30am - 4:30pm

0333 344 24 27

Содержание HANDYWASH SEHW3KA1

Страница 1: ...S E H W 3 K M 1 S E H W 3 K A 1 I n s t a l l a t i o n M a n u a l I s s u e 1 2 0 1 7 S E H W 3 K A 1 M o d e l S h o w n STROM LIMITED www stromltd com H A N D Y W A S H...

Страница 2: ...ated Current 13A Recommended Cable Size 1 5mm2 Thermal Cut Out 65o C Dry Heating Protection 70o C Hot Water Flow 0 5L 2L Per Minute Dependent On Required Temp IP Rating IPX4 Working Pressure 0 2 6 Bar...

Страница 3: ...d be assessed by a qualified electrician and the device should not be used until the unit or wiring has been repaired The minimum water supply available at the point of install is 0 2 Bar If at any ti...

Страница 4: ...Arm Electrical Terminal Block Water Valve Block Micro Switch Heating Element Thermal Cut Out Water Inlet Water Spray Arm Electrical Terminal Block PCB Cover Micro Switch Heating Element Thermal Cut Ou...

Страница 5: ...nd laws in place at the time of installation ACTION 1 ACTION 2 ACTION 3 1 To connect the Sprayer Spout start by ensuring the temperature control dial is set in the off position Remove the two screws a...

Страница 6: ...over of the unit make sure that there are no leaks from the cold inlet connection Place the front cover back on to the unit whilst still ensuring the temperature control dial is still in the off posit...

Страница 7: ...he tap Turning the temperature dial towards hot will give you hot water the further towards hot you turn the temperature dial the faster hot water will come out of the tap however the higher the flow...

Страница 8: ...of 12 months from the date of purchase The unit is only guaranteed if the water heater has been installed and maintained in accordance with these instructions Full guarantee information can be found...

Страница 9: ...NOTES...

Страница 10: ...NOTES...

Страница 11: ...NOTES...

Страница 12: ...w w w s t r o m l t d c o m STROM LIMITED www stromltd com...

Отзывы: