background image

• 

Your 

Strom Limited

 water heater 

MUST

 be installed and maintained regularly by a qualified 

professional in accordance with current electrical and plumbing regulations.

• 

If the chloride content exceeds 200ppm a filtration system should be fitted, failure to do so may 
invalidate your warrenty.

• 

This device has been designed for internal use only, if the system may be exposed to frost please 
drain down the system completely, and 

DO NOT

 attempt to use the device if you suspect it is frozen.

• 

Always ensure that the flow temperature is not excessive before use. If the water is too hot please 
increase the flow rate and wait for the temperature to reduce.

• 

As part of the product maintenance regularly clean the filter washer provided, failure to do so may 
reduce your flow rate over time.

• 

The HandyWash is not designed for modification in any way, please do not fit anything to the unit 
unless otherwise recommended.

• 

When comissioning the water valve should be adjusted to increase or decrease the water flow to 
the unit, this in turn will control the temperature of water from the outlet, slower increases the 
temperature, faster decreases the temperature. 

• 

Each unit is tested at our factory before its departure, a little residual water is normal, and the product 
should be flushed through before use.

• 

Never try to operate this device if your water supply is blocked or turned off, doing so could cause 
premature failure of your device.

• 

Any damage to the wiring or integrity of your device should be assessed by a qualified electrician, and 
the device should not be used until the unit or wiring has been repaired.

• 

The minimum water supply available at the point of install is 0.2 Bar.

• 

If at any time the water heater begins to overheat or produce water too hot for use and increasing 
the flow doesn’t cure the problem please isolate the electrical supply and consult your installer or our 
technical team immediately.

B E F O R E   I N S TA L L AT I O N

This installation must only be performed by a qualified electrician and installed to all relevent national 
and local electrical and plumbing regulations. Failure to do this could render the install both illegal and 
dangerous. Before installation please ensure the following:

1. 

Your 

Strom Limited

 appliance is intact, and the fittings are supplied & complete.

2. 

Please make sure the mains power supply, water pressure, earthing condition, and cabling reach the 
standards required for installation as required by all relevent regulations & laws.   

3. 

The appliance must be properly earthed in accordance with all current regulations and laws.

4. 

If the unit is not to be used for a prolonged period of time please drain down and isolate the electrical 
supply of the product. 

5. 

Position the unit upright with all plumbing connections at the bottom of the unit.

6. 

During the installation please test water flow is achieved at the tap before connecting the power 
supply. If the heater is activated without water supply the unit may be damaged.

7. 

Check incoming mains water pressure, if greater than 6 bar please reduce the pressure with a 
pressure reducing set available from your merchant. Failure to do so may damage your device & 
render your device warranty void.

Содержание HANDYWASH SEHW3KA1

Страница 1: ...S E H W 3 K M 1 S E H W 3 K A 1 I n s t a l l a t i o n M a n u a l I s s u e 1 2 0 1 7 S E H W 3 K A 1 M o d e l S h o w n STROM LIMITED www stromltd com H A N D Y W A S H...

Страница 2: ...ated Current 13A Recommended Cable Size 1 5mm2 Thermal Cut Out 65o C Dry Heating Protection 70o C Hot Water Flow 0 5L 2L Per Minute Dependent On Required Temp IP Rating IPX4 Working Pressure 0 2 6 Bar...

Страница 3: ...d be assessed by a qualified electrician and the device should not be used until the unit or wiring has been repaired The minimum water supply available at the point of install is 0 2 Bar If at any ti...

Страница 4: ...Arm Electrical Terminal Block Water Valve Block Micro Switch Heating Element Thermal Cut Out Water Inlet Water Spray Arm Electrical Terminal Block PCB Cover Micro Switch Heating Element Thermal Cut Ou...

Страница 5: ...nd laws in place at the time of installation ACTION 1 ACTION 2 ACTION 3 1 To connect the Sprayer Spout start by ensuring the temperature control dial is set in the off position Remove the two screws a...

Страница 6: ...over of the unit make sure that there are no leaks from the cold inlet connection Place the front cover back on to the unit whilst still ensuring the temperature control dial is still in the off posit...

Страница 7: ...he tap Turning the temperature dial towards hot will give you hot water the further towards hot you turn the temperature dial the faster hot water will come out of the tap however the higher the flow...

Страница 8: ...of 12 months from the date of purchase The unit is only guaranteed if the water heater has been installed and maintained in accordance with these instructions Full guarantee information can be found...

Страница 9: ...NOTES...

Страница 10: ...NOTES...

Страница 11: ...NOTES...

Страница 12: ...w w w s t r o m l t d c o m STROM LIMITED www stromltd com...

Отзывы: