BAM/CPM/SUM/UNM/ZPM
II/15
GB
2.9 Spare parts service
Visit our website www.schneider-airsys-
tems.com/td/ for the latest version of all ex-
ploded drawings and spare parts lists for our
products. If you have any special questions,
please consult the Schneider Airsystems Ser-
vice centre in your country (addresses in the
service appendix) or your local dealer.
E
Compressor runs
continuously.
Intake filter badly contami-
nated.
X
Clean or replace intake filter.
Air consumption of compressed
air tools is too high.
X
Check the air consumption of the
tools. Contact the service partner
Leakage at compressor.
X
Locate leak, contact service part-
ner.
Excessive condensate in the
vessel.
X
Drain the condensate (see
Chap. 2.6.5).
Compressed air line leaky:
X
Check compressed air line, plug
leak.
Condensate drain valve is open
or missing.
X
Close or replace.
F
During operation,
compressed air
escapes via the
load-relieving valve.
Load-relieving valve leaky.
X
Clean or replace load-relieving
valve.
G After the switch-off
pressure is reached,
compressed air
escapes via the
load-relieving valve
until switch-on
pressure is reached
Check valve insert leaky or
defective.
X
Clean or replace the check valve
insert (see Chap. 2.6.11).
Check valve is damaged.
X
Replace check valve.
H Compressor
switches on fre-
quently.
Excessive condensate in the
pressure vessel.
X
Drain the condensate (see
Chap. 2.6.5).
Compressor overloaded.
X
See item E
I
Safety valve blows
out.
Vessel pressure is higher than
the set switch-off pressure.
X
Have the pressure switch reset/
replaced by a qualified person.
Safety valve is defective.
X
Replace safety valve or contact
service partner.
J
Compressor over-
heats.
Air supply not sufficient.
X
Ensure sufficient ventilation.
Cooling fins on cylinder (cylin-
der head) contaminated.
X
Clean cooling fins on cylinder
(cylinder head).
Duty cycle too long.
X
Switch off compressor.
K Oil-lubricated com-
pressor: the oil
level rises without
oil having been
added.
Condensate collects in the oil.
X
Compressor is too large, contact
service partner.
High humidity.
X
Change oil.
L
V-belt driven com-
pressor: unusual
running noises.
V-belt or belt disc is scraping
against belt guard grating.
X
Look for point of contact, remedy
error
V-belt sags.
X
Tighten the V-belt (see
Chap. 2.6.10)
Problem
Cause
Remedy
Содержание STROCOMP 400
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 18: ...I 14 CPM 400 10 20 W RUS 1 5 1 6 1 6 1 1 5a 2 3 1 7 10 L 01 02 03 04 06 07 08 09 10 11 12 13 14 15 18 19 20 21...
Страница 73: ...BAM CPM SUM UNM ZPM II 53 RUS 1 2 3 Schneider Druckluft GmbH 1 X X X X X X X X...
Страница 78: ...II 58 BAM CPM SUM UNM ZPM RUS 8 2 7 2 2 8 X B X C X X X A X D X 2 4 4...
Страница 79: ...BAM CPM SUM UNM ZPM II 59 RUS E X X X X 2 6 5 X X F X G X 2 6 11 X H X 2 6 5 X E I X X J X X X...