For a loop stroke of 2.3–3.0 mm, the needle stroke must be set to that the left
side of the needle’s eye is approx. 1.0 +0.5 mm away from the large gripping
finger when the tip of the large gripping finger is above the centre of the needle
Adjusting the needle stroke (Fig. 6, Fig. 7 and Fig. 9)
.
The head cover must be removed for the adjustment. After removing (hex key
size 4) screw
(1)
, the ball pin
(2)
shown in
adjusted using a slotted screwdriver.
In the horizontal position, insert the ball pin so that the slot of the ø6 bolt stands
vertically beneath the ø7 bolt.
Rotating it clockwise will result in a larger needle stroke while turning it in the
opposite direction will create a smaller needle stroke.
The distance between the ball pin and needle shaft is 2 ±0.5 mm. After
adjusting the needle stroke, the needle lever must be configured as described in
section “3.2.1 Assembly”.
Tighten the screw
(1)
Check the looper and needle movement by turning the main shaft using the
handwheel.