19
MA_VEB100-3_A2_181015_en
3.4.3
At the moment when the loop is picked up, the gripping finger must lie
0.1–0.2 mm above the needle. This must also be observed when changing
the needle thickness. It is essential to prevent needle contact from occurring!
Adjusting the looper (Fig. 9)
The horizontal distance from the large gripping finger to the eye of the needle
should be 1.5 +0.5 mm
. On the left side where the loop is released, the
needle must pass centrally in between the two gripping fingers. These values
can be adjusted by turning and moving the adjusting cam
and rotating
the looper shaft against the head of the connecting rod
Check the looper movement by carefully turning the main shaft using the
handwheel!
Check that all fastening screws are firmly installed!
Fig. 9
Содержание VEB100-3
Страница 4: ......
Страница 8: ...4 MA_VEB100 3_A2_181015_en...
Страница 15: ...11 MA_VEB100 3_A2_181015_en Fig 1...
Страница 20: ...16 MA_VEB100 3_A2_181015_en Fig 7...
Страница 42: ......