CHAPTER 6
6.3.9 Err
09
Indicates that the meter has found multiple rear VSL Vulcoders.
Possible Causes:
1.
More than one rear VSL Vulcoder is attached at the same time. (During sequencing or
powering up the meter).
What to Do:
1.
Disconnect the VSL Vulcoders and then reconnect.
2.
Manually sequence the system.
3.
See electronics installation section for proper installation procedure, (Section 1.6).
6.3.10 Err
10
Communication error between the meter and the VSL Vulcoder. The VSL Vulcoder is in a “locked”
state.
Possible Causes:
1.
Faulty VSL Vulcoder
What to Do:
1.
Run Test 2 from the V600 Meter Test Procedures, (Section 3.5.3).
2.
Replace VSL Vulcoder.
6.3.11 Err
11
The meter “watchdog” system is not running
Possible Causes:
1.
New or recently repaired meter.
What to Do:
1.
Turn the meter off and then on to cycle power in system.
2.
If Err 11 is still displayed, replace meter.