CHAPTER 3
49
3.3.4
SETTING THE POST CALIBRATION
Post Calibration is a useful tool for changing the calibration after weight has been removed. It can
also be used by shop personnel after the truck has returned and there is no load to use for the Cal
Weight or Cal Number methods. To use this method of calibration, the driver needs to load up the
truck and take it across a platform scale. The driver then writes down the weight displayed on the
platform and the weight displayed by the meter. These two values can then be used to change the
calibration, even after the load has been removed.
Note:
Gross Weights can be only be used for Post Calibration.
Procedure To Set The Post Calibration:
Enter the
SETUP / CALIBRATE
Menu, (Section 3.3).
Press the
CYCLE
button until
SET: POST CAL
is displayed.
Press the
ENTER
button to select the
SET: POST CAL
option.
Press the
CYCLE
button to advance to the desired channel.
Press the
ENTER
button to select the desired channel.
June 21, 2006
VULCAN ON-BOARD SCALES 1-800-237-0022
Doc. 44-10032-001 Rev. C
©
STRESS-TEK, INC. 2006