CHAPTER 1
15
ORANGE
CABLE
BLACK
CABLE
LOAD CELL
LOAD CELL
Figure 1-L
Rear
VSL Vulcoder Configuration
WARNING:
If installing the meter in a vehicle with a
positive ground
electrical system, the
meter chassis, mounting bracket, and mounting fasteners
MUST
be electrically isolated from
the vehicle chassis.
9.
Find a suitable location for the meter and install the mounting bracket. Secure the VSL
Vulcoder cable so it does not obstruct other in cab equipment and strain relieve. Unplug the
terminal block from the back of the meter, strip the wires, and connect the VSL Vulcoder wires
to the terminal block (refer to Figures 1-M and 1-N). Secure the power cable so it does not
obstruct other in cab equipment, strain relieve the power cable, and
cut
to length. Strip the
wires, and make all wire connections to the terminal block (refer to Figures 1-M and 1-N).
Note:
Cut the shield wire off when stripping wires.
Do not
plug the terminal block into the
meter at this time.
10.
Disassemble the positive fuse holder, (red wire). Apply grease to the positive connector at the
battery post to inhibit corrosion. Connect fused power leads directly to battery posts for best
operation. If not connecting directly to the battery, be sure to use a location that has the proper
voltage available at all times, and never more than 29 Vdc.
Note:
Vulcan V600 meters are
configured to be used in
12 Vdc
system using
2 amp
fast blow fuses in both power and
negative leads. To use the V600 meter in a
24 Vdc
system, the
2 amp
fast blow fuse must be
replaced with a
1 amp
fast blow fuse in both power and negative leads. Refer to Section 7.2
“System Specifications.”
Do not
connect the power cable to a power source activated by the
key switch, power
should
be supplied at all times.
June 21, 2006
VULCAN ON-BOARD SCALES 1-800-237-0022
Doc. 44-10032-001 Rev. C
©
STRESS-TEK, INC. 2006