9.6 Schematic & Wiring Examples
9.6.1
2
X
D
IRECT HEATING CIRCUITS
Legend
Required Parameter Changes
Every system requires different parameter settings, for the above system change the following parameters.
System Type:
-
Parameter
P.01:
Set to 4.
-
Parameter
P.09:
Set to 1.
9.6.2
1
X
D
IRECT HEATING CIRCUIT
&
1
X DHW PRIMARY CIRCUIT WITH PUMP
Legend
Required Parameter Changes
Every system requires different parameter settings, for the above system change the following parameters.
Configuration Type:
-
Parameter
B02 :
Set to 8 for 70, 125 & 320 models ; Set to 5 for 220 model.
-
Parameter
B08 :
Set to 1.
System Type:
-
Parameter
P.09:
Set to 1.
72
– Room Thermostat 1
st
Zone
72b
– Room Thermostat 2nd Zone
138
– Outside Sensor
307
– Heating Pump 1
st
Zone
306
– Heating Pump 2
nd
Zone
I
– ISPESL Safety Devices
72
– Room Thermostat
138
– Outside Sensor
155
– DHW Tank Sensor
130
– DHW Primary Pump
300
– DHW Secondary Pump
306
– Heating Pump