Содержание IECS series

Страница 1: ... ...

Страница 2: ...leaning and user maintenance shall not be made by children without supervision 10 Disconnect the appliance from its power source during service and when replacing parts 11 The appliance must be installed 2 3m above floor 12 Warning before obtaining access to terminals all supply circuits must be disconnected 13 If the supply cord is damaged it must be replaced by the manufacturer its service agent...

Страница 3: ...2 3 4 5 6 Name of air conditioner components Preparation before installation Installation of unit Test run Maintenance and service 24 23 11 8 1 4 7 Symptom analysis and treatment 8 Electric installation 29 26 Appendix Unit Packing List ...

Страница 4: ...it shall be placed in the location unavailable by the child so as not to cause hazard 5 Do not sprinkle the water or other fluid on the unit otherwise it may lead to electric leak risk 6 Do not touch this unit with wet hand otherwise it may lead to electric shock 7 In stormy weather please cut off the unit main power supply switch otherwise it may lead to lightning risk and therefore damage the un...

Страница 5: ...lead to serious accident 4 In case of failure of unit the user shall timely report to the service center of our company for consultation and repair rather than repairing by himself the repairing of unit by non professional staff may lead to personal injury or unit damage 5 When cleaning the unit do not use benzene diluent or chemical cloth to wipe the operation panel otherwise it may lead to fadin...

Страница 6: ...he power supply before maintenance of unit 4 Do not touch the exhaust side pipe fittings to avoid scalding since the temperature may be more than 100Centigrade 5 The sharp edge and fin surfaces are harmful which must not be touched 6 Do not move the unit at will if no instruction of professional staff so as to accident and device damage 7 Do not touch the rotating fan blade with water or other art...

Страница 7: ...setting indication lamp Operation Defrosting Timing Protection Remote control signal receiving window Emergency key The protection lamp illuminates when the water is filled Defrosting pre heating light LED display light board Digital pipe display light board SW2 1 2 3 4 5 6 7 8 ON Operation indication light Defrosting pre heating light Emergency key Digital display pipe Timing setting light Operat...

Страница 8: ...M SWING TURBO TIMER AIR FLOW SLEEP HOLD CLEAN LAMP Before Cover is Flipped Down After Cover is Flipped Down ...

Страница 9: ... the sleep key to sleep the wind speed will automatically switch to low speed but the pressing of wind speed key except dehumidification mode It is set as non lock state in default when pressing this key the remote controller circulates in sequence of Lock to Cancel lock to Lock If the lock key is activated all keys of remote controller other than lock key does no function Note when the lock key i...

Страница 10: ...indicates the battery is used up take out the used battery and replace with new one There is no air conditioner receiving sound after transmitted the signal The display screen becomes obscure In case of above conditions it indicates the battery is used up take out the used battery and replace with new one Note In case of operation failure of remote controller please replace with new battery and re...

Страница 11: ...or unit 1 Install at the place where can not be directly exposed to the sunshine if inevitable please mount the sunshade facility to avoid direct exposure to the sunshine 2 The noise and air flow generated by the unit will not affect the neighbor 3 Convenient connection of indoor and outdoor unit and for ease of connection of power supply 4 Do not install at the place where the inflammable gas may...

Страница 12: ...s than outdoor units When there are barriers at front side and both sides do not use the dimensions shown in the figure Please refer to the right figure o 3 0 Ab ve 0 Ab ve 5 0 o 1 0 Above 300 Above 500 Above 500 Maintenance space 2 Multi unit installation unit mm A Parallel setting Above 300 Above 500 Below 10 pcs Above 300 Above 1500 Above 5000 Above 500 Above 5000 B Multi row arrangement C Blow...

Страница 13: ...ng or cooling effect and failure due of outdoor unit heat exchanger due to inadequate air flow A When there is wall nearby please locate the air exhaust facing the wall and keep about 500mm distance from the wall B When the air exhaust is affected by strong wind or wind direction it is necessary to change the air intake unit position to make the exhaust port perpendicular to the wind direction 3 P...

Страница 14: ...l or foaming polyethylene with the thickness of more than 10mm If more than 10mm please collect them at the position of inlet of ceiling 1 This indoor unit can be mounted on the ceiling of 2 5 3 5m high but when the ceiling height is higher than 2 7m the tape must be sued for site setting 2 Install and use the hoisting bolt check whether the installation position can support the unit weight If not...

Страница 15: ... for installation In case the ceiling is mounted a The dimensions of ceiling opening please refer to installation drawing b Firstly complete all pipelines connecting with indoor unit refrigerant pipe and drain pipe and electric wires connection pipes of indoor and outdoor units before installation for ease of connection with the indoor unit after installation c Reinforce the ceiling from the ceili...

Страница 16: ... be unable to work which may lead to drip B When there is installation position on the ceiling Be sure to use bolt and nut separately at upper and lower head of the hanging bracket seat to firmly fix the hanging bracket seat use locating plate 7 to avoid the washer coming off Attach the hanging bracket seat to the hoisting bolt be sure to use bolt and nut separately at upper and lower head of the ...

Страница 17: ... the air return grating and then pull up the other end of button See the figure below 2 Pull up the grating for about 45 degrees and take down the air return grating on trim panel See the figure below Take down the seal cover on angle pull out the seal cover as shown in figure below B Install the trim panel on indoor unit As shown in the figure below align the position of swinging baffle motor on ...

Страница 18: ...ating and cap A Install the air return grating B Install in reverse sequences to Preparation of trim panel While Install in reverse sequences to Preparation of trim panel While rotating the air return grating it can be installed in 4 directions If necessary to adjust the installation direction of air return grating or required by the user the installation direction can be changed No gap allowed Ad...

Страница 19: ...n of unit 4 Installation of unit Overall dimensions diagram for the outdoor unit 19 17 Unit mm 1 0 A B E D C F 1030 432 788 707 389 370 F B C D E 8QLW 0RGHO A 1 0 Overall dimensions diagram for the outdoor unit 1 7 ...

Страница 20: ...llation of unit 4 Installation of unit 18 Unit mm 907 400 1330 585 362 A E D C B 1 7 Unit mm 1055 400 995 694 372 347 A F B C D E 8QLW 0RGHO 1 7 C Overall dimensions diagram for the outdoor unit 1 7 8QLW 0RGHO ...

Страница 21: ...Up to 15 ...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...IECS ...

Страница 33: ... drainage hose 2 hose clamps 5 ribbons 4 hoisting rods Note The details refer to the actual article Attachment package 2 1 Installation and Operation Instruction including the product after sales service card 1 remote controller 1 pair of 7 batteries Cooling heating machine additional 1 water plug 1 drainage bent pipe Attachment package 3 a single joint thermal insulation pipe each for high and lo...

Страница 34: ...ENVIRONMENTAL TECHNOLOGIES LLC 17702 Mitchell North 101 Irvine CA 92614 USA Tel 714 795 2830 Fax 714 966 1649 info streamlinebyomega com www streamline omega com IECSN3A IM1N0517 ...