InTRODUCTIOn

Please read these assembly instructions thoroughly before commencing the construction. Double check all dimensions, levels and bolting 
locations before cutting, screwing or bolting structural members. It is recommended that the persons erecting the structure have had some 
previous building experience because some modifications to the existing house structure are required.

ATTACHInG TO An EXISTInG STRUCTURE

The builder is to ensure the existing house/structure is of a suitable 

structural  integrity  and  complies  with  all  the  relevant  Australian 

Building  codes  and  standards.  For  more  information  regarding 
the suitability of the house structure to accommodate the Stratco 

Attached Clearspan Gable, consult a structural engineer or a building 
authority. It is the builder’s responsibility to ensure that the existing 

house roof structure is strengthened correctly. 

Refer  to  section  2.1  if  attaching  Clearspan  Gable  on  its  side  to  a 
house, section 2.2 if attaching on its end to a house or refer to both 

sections if attaching the gable on its side and end. 

Attaching On Side To House

A Stratco Clearspan attached on its side to a house is attached to 

the existing eaves overhang at the fascia, or to an existing wall if 
height permits. 

The first objective in the construction is to fix a structural side beam 

along the fascia or wall, to which the Gable Unit is attached. 

Most existing houses have not been designed for the attachment of 
portal framed gables to their side, therefore additional strengthening 

of the house rafters must be performed. 

In order to strengthen the existing house rafters, the roof tiles or 
roof sheets need to be lifted to expose the roof frame. Steel rafter 
brackets and channels are then bolted along the house rafters. Refer 
to section 2.1.1. 

A 150mm Outback beam is bolted to the strengthening brackets at 

the fascia. Once the 150 attachment beam is secured to the house, 
the Gable Unit can be erected and fastened to the beam. 

Rafter Strengthening

The first step is to determine the number of rafters which need to 

be strengthened and their location relative to the unit. You will have 
to lift some roof tiles or roof sheets to discover the rafter positions 

and spacings. The number of rafters which need to be strengthened 
is determined by the builder, however spacing is recommended not 
to exceed 1200mm. 

Note:  It  is  the  builder’s  responsibility  to  ensure  the  existing 
rafters  and  fascia  are  adequately  reinforced  and  strengthened  to 

accommodate  any  additional  attached  structure.  The  reinforcing 
method must be approved by the appropriate council or engineer. 

It is recommended an adjustable rafter strengthening bracket is used 
in  conjunction  with  an  extension  channel,  as  shown  in  (Figure  3). 

The adjustable rafter strengthening bracket is shown in (Figure 2). 

Please note that this bracket may not be suitable for applications 
where the front face of the house gutter is higher than 120 mm. In 
these cases please contact Stratco for alternative solutions. 

The adjustable rafter strengthening bracket allows for an adjustment 

of pitch in the range of 15 to 30 degrees. The distance the bracket 
extends past the fascia is also adjustable to allow for standard gutters 
(minimum extension) or box gutters with a width of up to 200mm. 

In  conjunction  with  rafter  strengthening  brackets  a  channel  is 
fixed to the side of the house rafter (Figure 3). The bottom end of 
the channel will be located at the base of the house rafter. Holes 

should be marked and pre-drilled in the channel to suit the location 
of  existing  holes  in  the  bracket.  The  channel  will  extend  beyond 

the bracket so additional holes are to be drilled in the channel at 
approximately 500mm centres.

Adjustable Rafter
Strengthening Bracket

Содержание Outback Gable

Страница 1: ... that retains water such as dirt or paving sand should be placed against the columns Care must be taken when determining the location of Stratco steel products so that they are not placed in close contact with sources of pollution or environmental factors that could affect the life of the steel Refer to the Selection Use and Maintenance brochure for more information lift the back of the gutter int...

Страница 2: ...L Provides decoration at the apex of the gable end frame BEAm FILLER Fills gap between intersecting Beams HEADER FLASHInGS Run along header beam to neatly finish the base of in fill panels pOST CAp Fills gap between post and beam pOST BRACKET Connects post to beam BOLTS Vary depending upon the connection ensure correct fixings are used GABLE BEAm BRACKET Connects rafters to header beam on an infil...

Страница 3: ...hors for column installation Other items not included in the standard kit are infill panels and accessories finials box gutters cover flashings and concrete Ridge Capping Flat Section Outback Deck Ridge Beam Ridge Knuckle Gable Rafter Valley Beam Angle Back Channel Beam Capping Gable Beam Bracket Header Beam Barge Cap Post Bracket Post Gutter Header Beam Bracket End Strut End Strut Plate 1 2 3 4 5...

Страница 4: ...hannels are then bolted along the house rafters Refer to section 2 1 1 A 150mm Outback beam is bolted to the strengthening brackets at the fascia Once the 150 attachment beam is secured to the house the Gable Unit can be erected and fastened to the beam Rafter Strengthening The first step is to determine the number of rafters which need to be strengthened and their location relative to the unit Yo...

Страница 5: ...r fixing all the brackets and channels the 150 attachment beam is fixed in place Prop up the 150 attachment beam in position with the double flange on top the beam will need to be located at a height on the bracket which allows clearance between the gable roof sheets and the gutter Fix to the end plates of the rafter bracket using two M12 bolts with the bolt head on the 150 attachment beam side In...

Страница 6: ...r at the rear of the unit is to be set back sufficiently from the house fascia to accommodate the house gutter and infill panel refer to Figures 22 and 23 If fixing a Clearspan Gable on its end to an attachment beam elevated to the existing house gutter height the attachment beam is to be as close as possible within 5mm to the outside face of the gutter Figure 24 The 150 attachment beam is fixed t...

Страница 7: ...suring the break is located in the top groove Figure 14 If attaching the valley beam to a header beam notch the capping so that it sits on top of the beam as shown in Figure 21 Pilot holes indicate screw locations as shown in Figure 11 Make sure that the two ends are flush at the connection leaving no gaps 4 0 VALLEY BEAm ASSEmBLY 4 1 Side Attached For side attached units fix the rafter to valley ...

Страница 8: ...s 10 x dia 15 Figure 16 The valley beam is fastened to the wall bracket with 10x16 hex head screws in the pre drilled holes while the opposite end is supported on adjustable construction props For units attached on the end to a fascia suspension brackets are positioned at either side of the gable opening at the spacing determined in Section 3 0 Figure 12 The top tab of the suspension bracket must ...

Страница 9: ...kets as explained in the Stratco Installation Guide Outback Flat Attached Verandah Patios Carports under Bracket and Filler Connections This can be done before valley beams are fixed in place Support the second valley beam on adjustable construction props but do not fix to the wall fascia or attachment beam until the front gable frame has been attached Fix the rafter to valley brackets to the beam...

Страница 10: ...n 14 for details of fixing infill panels to gable frames note 1 A custom made soaker flashing will need to be ordered to the required dimensions The rafter setback will need to be adjusted to suit 2 Do not form stop ends at either end of the soaker flashing 3 Soaker flashing is not to come in contact with the base of the house gutter 5 2 2 2 Header Flashing When a gable is fixed at the rear to an ...

Страница 11: ...ntres ensuring that the top of the back channel is in line with the bottom of the beam chamfer as shown in Figure 25 The back channel should run 34mm past the end of the beam at both ends of the ridge beam If there is no rear portal frame finish the back channel flush at one end Fasten 10x16 hex head self drilling screws at 500mm centres along the double flange of the ridge beam Figure 25 In the c...

Страница 12: ... hole as shown in Figure 29 Measure from the underside of the beam to the top of the brick and cut posts to this length at each post location 8 1 68 Outback Column If 50x50 mm square hollow sections SHS have been supplied the fluted 68 Outback columns will need to be reinforced Cut the 50mm SHS 75mm shorter than the fluted post and slide into the column Ensure the square section is positioned insi...

Страница 13: ... columns in position but do not bolt to the concrete slab at this stage Footing brackets are available when fixing posts to an existing concrete slab Establish the column lengths by measuring the distance from the underside of the fascia beam to the concrete slab less the thickness of the footing plate or 20mm for Outback footing plate 9 1 68 Outback Column Footing plate For non reinforced 68 Outb...

Страница 14: ...utter straps at maximum 1000mm intervals attaching to the top of the decking with rivets Waterproof rivets with silicone Figure 32 down to beam capping Back channel fixed upside Outback Deck Outback Deck Gable Frame Front Facia Beam Header Beam Beam Capping Valley Beam Column Gable Beam Bkt 12 1 Flat Roof If Applicable Attach the decking to the flat roof verandah first as laid out under DECKING Ou...

Страница 15: ...an Gable When attaching the decking to the gable start from the rear on one side of the gable Fix the deck to the angled back channel at the ridge and to the capping at the valley beam If the deck of the flat roof section runs perpendicular to the valley beams align the 14 1 Header Beam With Gutter Attach the header flashing to the rear gutter lip with rivets Infill panels are fixed through the to...

Страница 16: ...apping is required at the ends of the unit attach the barge cap by screwing the lower lip to the rafter and rivet the top section to the deck as shown in Figure 39 Mitre the barge at the apex of the gable for a neat finish Run the barge cap along the gable section to where it meets the flat verandah deck and finish neatly Before securing columns in position ensure a minimum fall of 1 in 500 12mm f...

Отзывы: