background image

Gutter Profile

Effective Cross 

Sectional Area 

Capacity (mm2)

Total Cross 

Sectional Area 

(mm2)

Round (dia mm)

Rectangular/ 

Square (mm)

Quad

115mm Quad

5,621

6,760

90

100 x 50

115mm Quad - Slotted

5,057

6,192

90

100 x 50

115mm Quad - Low Front

4,307

5,429

75

75 x 50

125mm Quad - NSW

6,488

7,833

90

100 x 50

125mm Quad - SA/NT

6,697

7,958

100

75 x 75

125mm Quad - Slotted

5,592

6,842

90

100 x 50

150mm Quad

8,685

10,088

125

100 x 75

175mm Quad

12,213

13,767

125

100 x 100

OG

125mm OG  

4,432

5,609

75

75 x 50

125mm OG - Slotted

3,374

4,432

65

75 x 50

150mm OG - Slotted

5,763

7,055

90

100 x 50

Half Round & Smoothline

150mm Smoothline

8,748

10,124

125

100 x 75

150mm Smoothline - Slotted

6,961

8,332

100

100 x 75

150mm Half Round

7,703

9,176

100

100 x 75

150mm Half Round - Slotted

7,126

8,597

100

100 x 75

Square

VC

5,712

6,893

90

100 x 50

VC - Slotted

4,412

5,594

75

75 x 50

LO-Square - Slotted

4,447

5,624

75

75 x 50

VFC

6,775

7,957

100

100 x 75

VFC - Slotted

5,475

6,657

90

100 x 50

VF - SA

7,839

8,970

100

100 x 75

VF - WA

7,333

8,444

100

100 x 75

VF - Slotted

5,475

6,657

90

100 x 50

HI-Square - Slotted

5,974

7,155

90

100 x 50

C-Square - Slotted

5,974

7,155

90

100 x 50

VT - Slotted

6,338

7,583

90

100 x 50

VFM - Slotted

6,711

7,888

100

100 x 75

Miscellaneous

Edge Gutter

14,856

16,833

-

-

Edge Gutter WA

9,151

10,936

-

-

HK

5,394

6,590

75

100 x 50

HK - Slotted

3,717

4,816

75

75 x 50

S

5,315

6,358

75

100 x 50

S - Slotted

4,609

5,622

75

75 x 50

Clickform - Slotted

5,102

6,303

90

100 x 50

450mm Girth OG Big One - Slotted

9,881

11,551

125

100 x 100

600mm Girth OG Big One - Slotted

26,345

28,615

125

100 x 100

Quarter Round

6,292

7,577

90

100 x 50

Quarter Round - Slotted

5,054

6,309

90

100 x 50

Table 2 | Cross Section Area

  

(mm

2

)

Minimum Downpipe Size

Содержание High Fronted Gutters

Страница 1: ...nage Domestic Installations It is also important that relevant State regulations are satisfied For example New South Wales legislation requires all gutter and downpipe installations be undertaken by a...

Страница 2: ...At the end of gutters normal height stop ends can be replaced by lower stop ends which reduce the depth of water able to collect in the gutter controlling overflow to these points Using an internal ou...

Страница 3: ...es FIGURE 5 Modified Stop End Internal Outlet Front Cut Down Stretch in The Back Face of The Gutter Front is Lower Than The Top of The Fascia Propriety Solution Sump Rainhead Front Spiggot Rear Exit G...

Страница 4: ...Charleville 170 Charters Towers 218 Cloncurry 172 Emerald 220 Goondiwindi 182 Gympie 228 Hughenden 199 Innisfall 254 Kingaroy 208 Longreach 189 Mackay 273 Mareeba 219 Mt Isa 169 Mt Morgan 225 Noosa 2...

Страница 5: ...lotted 7 126 8 597 100 100 x 75 Square VC 5 712 6 893 90 100 x 50 VC Slotted 4 412 5 594 75 75 x 50 LO Square Slotted 4 447 5 624 75 75 x 50 VFC 6 775 7 957 100 100 x 75 VFC Slotted 5 475 6 657 90 100...

Страница 6: ...re followed Adequate fall towards the downpipes must be given to gutters a minimum of 1 in 500 for eaves gutters and 1 in 200 for internal gutters The installer must ensure that the correct number of...

Страница 7: ...essential to maintain the good looks of all Stratco steel products and to ensure you receive the maximum life span possible in your area Gutters must be regularly cleaned to prevent the build up of le...

Отзывы: