3
MINIMUM CLEARANCES
Figure 1: Minimum Clearances
ENVIRONMENTAL REQUIREMENTS
•
The 360mc and 400mc system are for indoor use only.
•
Maximum temperature of operating environment: 85°F (29°C)
•
Maximum dew point: 78°F (25°C)
HEAT OUTPUT
Heat dissipation of the system occurs mostly through the top of the machine. Heat output is material dependent
due to the various temperatures maintained in the build chamber.
Side Clearance
Minimum 30 inches (76.29 cm) on each side
Rear Clearance
Minimum 12 inches (30.28 cm)
Front Clearance
Minimum 36 inches (91.44 cm)
Overhead Clearance
Minimum 28 inches (71.12 cm)
Material Type
Heat Output
ABS
9,600 BTU/hr
PC
12,000 BTU/hr
PPSF
20,000 BTU/hr
30 inches
(76.29 cm)
30 inches
(76.29 cm)
12 inches
(30.28 cm)
36 inches
(91.44 cm)
Front
Rear
28 inches (71.12 cm) minimum for overhead clearance