background image

8

Figure 4: Main power connection block diagram

LAN REQUIREMENTS

A LAN connection is required for communication and file transfer functions.

• 

The LAN connection is a 100 base T, Ethernet protocol, RJ45 connector. One 25-ft. CAT5, 10/

100 base T cable is supplied with the system, located in the Startup Kit.

• 

The 360mc/400mc will function in either DHCP or Static IP configurations.

Note: 

Systems configured with a network option of UPnP=ON will occasionally 

broadcast a unique system identifier across the network for use by the Insight 
FDM Control Center software application.

Refer to Insight user information for workstation requirements. 

Содержание Fortus 360mc

Страница 1: ...Part No 107167 0011_REV_A Fortus 360 400mc SITE PREPARATION GUIDE ...

Страница 2: ... document may be photocopied reproduced or translated into another language without the prior written consent of Stratasys Inc All drawings and information herein are the property of Stratasys Inc All unauthorized use and reproduction is prohibited TRADEMARK ACKNOWLEDGMENTS Stratasys Insight FORTUS and FDM are registered trademarks of Stratasys Inc FORTUS 360mc FORTUS 400mc FDM 360mc FDM 400mc are...

Страница 3: ...ATIONS 4 STRATASYS EXTERNAL AIR COMPRESSOR JA 100 SPECIFICATIONS 5 Dimensions and Weight 5 ELECTRICAL REQUIREMENTS 6 Nominal Voltage Level 6 Power Quality 6 Electrical Requirements JA 100 External Air Compressor 6 Transformer JA 100 External Air Compressor North America Only 6 TRANSFORMER INSTALLATION 7 LAN REQUIREMENTS 8 RECEIVING THE SYSTEM 9 INSPECT CRATE FOR DAMAGE 9 PREPARING FOR INSTALLATION...

Страница 4: ...iv Remove system from shipping base 12 SERVICE CONNECTIONS 13 ...

Страница 5: ...n electrical fires Know local procedures for first aid and emergency assistance at the customer facility Use adequate lighting at the equipment Maintain the recommended range of temperature and humidity in equipment area Do not use this product in an environment containing volatile or flammable compounds Revision Date Description of Changes E June 2010 Format changed and document update F December...

Страница 6: ...ial auto changeover feature and increases the envelope size to 16 x 14 x 16 inch 406 x 355 x 406 mm Operator Control Panel HOW TO USE THIS GUIDE This guide provides information for selecting an appropriate location and for connections to the Fortus 360 400mc systems Both systems throughout this guide will be referred to as the 360mc 400mc This guide also provides instructions for unpacking and pre...

Страница 7: ...ENTS DIMENSIONS AND WEIGHTS Make sure that the installation site floor space can accommodate the printer s weight and dimensions plus required clearances see Minimum Clearances below Crated Width 58 25 inches 147 96 cm Depth 42 75 inches 108 59 cm Height 86 5 inches 219 71 cm Uncrated Width 50 5 inches 128 cm Depth 35 25 inches 89 64 cm Height 77 25 inches 195 63 cm Shipping Weight 1511 pounds 687...

Страница 8: ...Heat output is material dependent due to the various temperatures maintained in the build chamber Side Clearance Minimum 30 inches 76 29 cm on each side Rear Clearance Minimum 12 inches 30 28 cm Front Clearance Minimum 36 inches 91 44 cm Overhead Clearance Minimum 28 inches 71 12 cm Material Type Heat Output ABS 9 600 BTU hr PC 12 000 BTU hr PPSF 20 000 BTU hr 30 inches 76 29 cm 30 inches 76 29 cm...

Страница 9: ...pply pressure must be less than 145 psi Non lubricated Non condensing DIN ISO 8573 1 Quality Class 5 or better is recommended to improve onboard filter life Connection The air source connection must meet dimensional standard A A 59439 for the quick disconnect female inch coupler A standard inch quick disconnect male plug A A 59439 is supplied with the system 2 Customer can use the Stratasys Extern...

Страница 10: ... Tank Compressor Dimensions Width 18 inches 47 cm Depth 28 inches 71 cm Height 34 inches 86 cm NOTE Allow a minimum of 4 inches 10 cm behind the compressor for proper cooling Compressor Weight 202 pounds 92 kg Drain Tank Dimensions Width 11 inches 28 cm Depth 11inches 28 cm Height 14 inches 36 cm Acoustic Level 50dB A Note The Stratasys external air compressor option includes an air hose and must ...

Страница 11: ...nd FIPS PUB 94 Customers which are unsure of their power quality need to contact their provider ELECTRICAL REQUIREMENTS JA 100 EXTERNAL AIR COMPRESSOR The optional external air compressor requires dedicated 50 60HZ 230 VAC Single Phase 15 Amp electrical service The air compressor includes an 8 ft 2 5m power cable requiring the installation of an AC service connector TRANSFORMER JA 100 EXTERNAL AIR...

Страница 12: ...nect to the transformer and from the transformer to the system including all connectors cables and proper strain relief Improper installation of a transformer or installation of a transformer not meeting system requirements may invalidate the warranty and or cause performance problems Note A neutral line is neither used nor valid in this configuration ...

Страница 13: ...5 ft CAT5 10 100 base T cable is supplied with the system located in the Startup Kit The 360mc 400mc will function in either DHCP or Static IP configurations Note Systems configured with a network option of UPnP ON will occasionally broadcast a unique system identifier across the network for use by the Insight FDM Control Center software application Refer to Insight user information for workstatio...

Страница 14: ...INSTALLATION REQUIRED TOOLS AND EQUIPMENT Basic hand tools Forklift of sufficient size to raise the system from the shipping base See Space Requirements on page 2 UNPACKING THE SYSTEM REMOVE SHIPPING MATERIALS 1 Using a phillips screwdriver remove the cover mount screws from the base of the crate See Figure 5 2 Carefully cut the shipping bands See Figure 5 Warning Wear safety glasses when removing...

Страница 15: ...e the cardboard cover See Figure 6 4 Remove the two end walls of the shipping container two part triple wall sleeve See Figure 6 5 Remove the two foam protectors from the top of system See Figure 6 Shipping Bands 5 Cover Mount Screws 12 FRONT ...

Страница 16: ...rapping and plastic bag from the system 7 Inspect the system exterior for dents and scratches Immediately report any damage to Stratasys and the shipping company Caution Use care when removing the plastic wrap to avoid scratching the system surfaces Foam protector 2 End wall 2 ...

Страница 17: ...s on its casters 3 Roll the system into its approximate operating location Caution Access the fork lift openings from the front of the system Note Position the system to allow at least three feet of clearance on all sides until the installation process is complete See Space Requirements on page 2 Final installation and setup must be accomplished by a qualified service representative Forklift openi...

Страница 18: ...electrical panel Do not terminate to hinged access door Figure 8 Rear view Warning A licensed electrician must perform all wiring from service connect to the transformer and from the transformer to the system including all connectors cables and proper strain relief Comply with all applicable local and national electric codes Do not apply power to the System until the Installation Service Represent...

Страница 19: ...14 Figure 9 Line Connections ...

Страница 20: ...materials and applications call 888 480 3548 or visit www stratasys com DOCUMENTATION FEEDBACK Customers resellers and Stratasys employees are encouraged to send comments about our documentation and training to c support stratasys com We greatly value your comments review all of them and use them to improve subsequent releases of the documentation In your email message please include the document ...

Отзывы: