Installation & Operation Guide
Vision.net RS232 Interface Port
4
OPERATION
Communication Modes
The Vision.net RS232 Serial Interface Port operates in one of two modes: Vision.net (binary)
or Show Control (ASCII).
The unit will sense the incoming protocol and automatically switch to the proper mode. Note
that it may take several messages from either the third-party system or the Vision.net Designer
PC before the RS232 Interface switches modes.
ASCII Codes For Vision.net Show Control Protocol
* Sending a second <cr> after a RA or LW command will automatically send the proper ST command
Vision.net Mode
Show Control Mode
8 Bit
8 Bit
1 Stop Bit
1 Stop Bit
19200 Baud
9600 Baud
Protocol: Binary
Protocol: ASCII
Vision.net
Command
RS232
Protocol
Vision.net
Command
RS232
Protocol
Start Preset
Toggle Down
Toggle Up
Learn Preset
Slider Level
Learn Submaster
Manual
Expander Group
Start Raise
Start Lower
Stop Raise/Lower
SP rrr pp tt<cr>
TD rrr ccc<cr>
TU rrr ccc<cr>
LP rrr pp<cr>
SL rrr ccc lll<cr>
LS rrr ss<cr>
MN rrr ggg lll … lll<cr>
EG rrr ee<cr>
EG rrr ee ff lll … lll<cr>
RA rrr qqq<cr>
LW rrr qqq<cr>
ST rrr qqq<cr> *
Record Blind
Lock Button
Unlock Button
Smart On
Smart Off
Define Room Link
Submaster Level
Take Control (sub)
Set Channel
Set Mode
Send Mimic
Console Button
Console LED
RB rrr pp ggg lll … lll<cr>
LB idd n<cr>
UB idd n<cr>
SN idd n<cr>
SF idd n<cr>
DR x fff rrr … rrr<cr>
SB rrr ss lll<cr>
TC rrr ggg lll … lll<cr>
SC rrr ccc lll rr<cr>
SM mm<cr>
MC idd n a<cr>
CB idd n a<cr>
CL idd n a<cr>