background image

 Strand Lighting Offices

The material in this manual is for information purposes only and is subject to change without notice.

 

Philips Strand Lighting assumes no responsibility for any errors or omissions which may appear in this

 

manual. For comments and suggestions regarding corrections and/or updates to this manual, please

 

contact your nearest Philips Strand Lighting office.

El contenido de este manual es solamente para información y está sujeto a cambios sin previo aviso.

 

Philips Strand Lighting no asume responsabilidad por errores o omisiones que puedan aparecer. Cualquier

 

comentario, sugerencia o corrección con respecto a este manual, favor de dirijirlo a la oficina de Philips

 

Strand Lighting más cercana.

Der Inhalt dieses Handbuches ist nur für Informationszwecke gedacht, Aenderungen sind vorbehalten.

 

Philips Strand Lighting uebernimmt keine Verantwortung für Fehler oder Irrtuemer, die in diesem

 

Handbuch auftreten. Für Bemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf

 

Korrekturen und/oder Aktualisierungen in diesem Handbuch, moechten wir Sie bitten, Kontakt mit der

 

naechsten Philips Strand Lighting-Niederlassung aufzunehmen.

Le matériel décrit dans ce manuel est pour information seulement et est sujet à changements sans préavis.

 

La compagnie Philips Strand Lighting n'assume aucune responsibilité sur toute erreur ou ommission

 

inscrite dans ce manuel. Pour tous commentaires ou suggestions concernant des corrections et/ou les

 

mises à jour de ce manuel, veuillez s'll vous plait contacter le bureau de Philips Strand Lighting le plus

 

proche.

Information contained in this document may not be duplicated in full or in part by any person without

 

prior written approval of Philips Strand Lighting Inc. Its sole purpose is to provide the user with

 

conceptual information on the equipment mentioned. The use of this document for all other purposes is

 

specifically prohibited.

Document Number: 

2-450200-020

Version as of: 

04 April 2012

Vision.net RS232 Serial Interface Port Installation & Operation Guide

 Strand Lighting - Dallas

 

10911 Petal 

Street

Dallas, TX 75238

Tel: 214-647-7880

Fax: 214-647-8030

 Strand Lighting - New York

 

267 5th 

Ave, 4th Floor

New York, NY 10016

Tel: 212-213-8219

Fax: 212-532-2593

 Strand Lighting - Asia Limited

 

Unit 

C, 14/F, Roxy Industrial Centre

 

No. 

41-49 Kwai Cheong Road

Kwai Chung, N.T., Hong Kong

 Tel: +852 2796 9786
Fax: +852 2798 6545

 Strand Lighting - Auckland

19-21 Kawana Street

Northcote, Auckland 0627

New Zealand

Tel: +64 9 481 0100

Fax: +64 9 481 0101

 Strand Lighting - Europe

 

Marssteden 152

Enschede 7547 TD

The Netherlands

Tel: +31 53 4500424

Fax: +31 53 4500425

Website

:

www.strandlighting.com

Содержание 63035

Страница 1: ...UJ 0 J z 0 a UJ 0 0 z 0 I I C z Strand Lighing RS232 Serial Interface Port Model 63035 ...

Страница 2: ... seulement et est sujet à changements sans préavis La compagnie Philips Strand Lighting n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s ll vous plait contacter le bureau de Philips Strand Lighting le plus proche Information contained in this document ...

Страница 3: ...nel e The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition f Do not use this equipment for other than intended use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breaker or other power disconnect device before installing any wiring Be sure that power is disconnected by removing fuses or turni...

Страница 4: ...iven a unique ID or address in order to interact properly The ID identifies the device on the network and allows the device to avoid network collisions when transmitting data Vision net RS232 Serial Interface Port Overview The Vision net RS232 Serial Interface Port Strand Part No 63035 allows integration with the Vision net Network using standard RS232 communication The RS232 Interface has the abi...

Страница 5: ...dard deep rough in box not included Secure with two supplied mounting screws Step 4 Snap faceplate into place A standard Windows compatible computer can be connected to the Vision net Network using the RS232 Interface Port The port accepts a standard one to one 9 pin serial cable up to 25 feet in length RS232 Interface Port PC Computer Pin 1 NU Pin 1 NU Pin 2 TX Pin 2 RD Pin 3 RX Pin 3 TD Pin 4 NU...

Страница 6: ...it 1 Stop Bit 19200 Baud 9600 Baud Protocol Binary Protocol ASCII Vision net Command RS232 Protocol Vision net Command RS232 Protocol Start Preset Toggle Down Toggle Up Learn Preset Slider Level Learn Submaster Manual Expander Group Start Raise Start Lower Stop Raise Lower SP rrr pp tt cr TD rrr ccc cr TU rrr ccc cr LP rrr pp cr SL rrr ccc lll cr LS rrr ss cr MN rrr ggg lll lll cr EG rrr ee cr EG ...

Страница 7: ...ear All Links 1 Do not clear ee Expander Group 0 15 mm Mode 0 All modes ff Index of First Channel 1 127 fff First Room 1 255 n Button LED 1 255 a Action 0 1 Off On or Button Up Down for Send Mimic Command 0 1 Button Down Up for Console Button Command 0 1 LED Off On for Console Button Command SPECIFICATIONS Electrical Input Power 18 26 VDC powered from Vision net network Current 20mA Temperature St...

Страница 8: ...Part No 2 450200 020 ...

Отзывы: