Step 7: Commissioning
Pressure test point
Use the oven burner. From inside the
oven remove the burner cowl. Remove
the small screw at the LHS of the
burner cradle. Slide the burner to the
left to access the injector. Connect
manometer to the injector and turn the
grill burner to full on to check pressure.
Replace in reverse order.
Burner aeration
All burners have fixed aeration and no
adjustment is possible.
Pressure setting
G20 Natural Gas @ 20 mbar
Electrical systems check
In the event of an electrical fault the
preliminary electrical system check
(earth continuity, short circuit, polarity
and resistance to earth) must be
carried out.
Ignition
The automatic ignition continues to
spark for a short time after the burner
has lit until the flame is established.
Oven
1. Push in and turn the control knob
anticlockwise to gas mark 9. The oven
light will come on automatically.
2. Adjust to the required setting.
3. The burner may not come on to a full
rate unless the oven door is closed.
The oven burner operates at a low
rate for up to 60 seconds until the
flame supervision device opens
and full gas rate is obtained.
Grill
1. Open the door, push in and turn
the control knob anticlockwise to
the full on setting.
2. Check condition of flame at low
setting.
When you first turn on the oven or
grill you may notice a smell and some
smoke which comes from the
protective coating of oil burning off
from some of the parts.
Before leaving the installation
Show the customer how to ignite the
oven and grill, and give them this
handbook.