background image

Electromagnetic compatibility

Instructions for use • C-MAC Monitor • NDQ566_EN_V1.0_02-2021_IFU_CE-MDR

42

Interference immunity
tests

EN/IEC 60601 test
level

Compliance

level

Electromagnetic envi-

ronment – guidelines

Field strengths from fixed
HF transmitters as deter-
mined by an electromag-
netic site survey 

a

 should

be less than the compli-
ance level in each fre-
quency range 

b

.

d = 1.2 √P

80 MHz to 800 MHz

d = 2.3 √P

800 MHz to 2.5 GHz

Interferences may occur in
the vicinity of equipment
marked with the following
symbol:

Note: At 80 MHz and 800 MHz, the higher frequency range applies.

Note: These guidelines may not apply in all situations. The propagation of electromagnetic
waves is affected by absorptions and reflections of buildings, objects, and people.

a

 Field strengths from fixed transmitters, e.g., base stations for radio (cellular/cordless) tele-

phones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broad-
cast cannot be predicted theoretically with accuracy. To assess the electromagnetic environ-
ment due to fixed transmitters, an electromagnetic site survey should be considered. If the
measured field strength at the location where the device is used exceeds the above compli-
ance levels, the device should be monitored to ensure proper function. If abnormal perfor-
mance is observed, additional measures may be necessary, such as re-orienting or relocating
the product.

b

 Over the frequency range from 150 kHz to 80 MHz, field strengths should be less than 3 V/

m.

9.5 Table 4 – Emission class and group

Guidelines and manufacturer’s declaration – Electromagnetic emissions

The product is intended for use in such an environment as specified below. The customer or
user of the product should ensure that it is used in such an environment.

Emission measurements

Compliance

Electromagnetic environment –
Guidelines

RF emissions as per CISPR 11

Group 1

The product uses RF energy only for
its internal function. Therefore, its RF
emissions are very low and are not
likely to cause any interference in
nearby electronic equipment.

RF emissions as per CISPR 11

Class B

The product is suitable for use in all
establishments including domestic
establishments and those directly
connected to the public low voltage

Harmonic emissions as per IEC
61000-3-2

N/A

Содержание C-MAC 8403ZX

Страница 1: ...Instructions for use C MAC Monitor 8403ZX en...

Страница 2: ...illustrations product descriptions and texts are the intellectual property of KARL STORZ SE Co KG Their use and reproduction by third parties require the express approval of KARL STORZ SE Co KG All ri...

Страница 3: ...eakage current 8 3 11 High light intensity 8 3 12 Electromagnetic interference 8 4 Product description 10 4 1 Product overview 10 4 2 Possible combinations 10 4 3 Technical specifications 12 4 4 Symbo...

Страница 4: ...5 7 5 Disposing of the product 36 8 Accessories and spare parts 37 8 1 Accessories 37 8 2 Spare parts 38 9 Electromagnetic compatibility 39 9 1 General notes on the operating environment 39 9 2 Table...

Страница 5: ...the product may be damaged Read the instructions for use of the combinable products carefully and follow all the safety notes and warnings 1 3 Scope This instruction manual is valid for Product name A...

Страница 6: ...f the upper respiratory tract or endotracheal intubation is indicated 2 3 Contraindications The use of laryngoscopes and video laryngoscopes is contraindicated if in the opinion of the responsible phy...

Страница 7: ...oduct for the following points before and after every use Completeness Good working order Rough surfaces left inadvertently Sharp corners Burred edges Correct assembly of the components Functionality...

Страница 8: ...patients users and third parties may be injured Do not store liquids near the product or on the product If liquid has entered the product pull out the plug and allow the product to dry completely 3 1...

Страница 9: ...ral devices e g antenna cables and external antennas should be used no closer than 30 cm from the product including cables specified by the manufacturer Observe the information on electromagnetic comp...

Страница 10: ...3 Mains connection 10 Control buttons 4 Reset button 11 Progress bar 5 SD slot 12 Function symbols 6 Status bar 13 USB port 7 Operating pilot lamp green 14 HDMI port 4 2 Possible combinations The pro...

Страница 11: ...MAC Video Laryngoscope MAC 3 8403AXC C MAC Video Laryngoscope MAC 4 8403BX C MAC Video Laryngoscope MAC 4 8403BXC C MAC Video Laryngoscope MIL 0 8403DXC C MAC Video Laryngoscope MAC 0 8403EXC C MAC V...

Страница 12: ...m Order no CMOS Video Rhino Laryngoscope 11101CM CMOS Video Rhino Laryngoscope 11102CM Video Esophagoscope 13303E Video units for urology Item Order no C View Video Cystoscope 11272VU C View Video Cys...

Страница 13: ...ower adaptor Weight Approx 130 g SD card Data rate 10 MB s Compatibility Compatible with SD and SDHC cards up to 32 GB class 4 or higher USB stick Compatibility USB 2 0 compatible FAT formatted up to...

Страница 14: ...M 52 45 30 50 11272V 11272VE 11272VU 11272VUE 40 34 25 50 11301ABX 52 45 30 30 11301BNX 40 40 35 50 11302BDX 52 45 30 50 11303BCX 20 5 25 50 11303BNX 52 45 30 50 11304BCX 52 45 30 50 13303E 52 45 30 5...

Страница 15: ...The device must not be modified in any way 4 4 2 Symbols on the product Symbol Meaning Type BF device Power socket CE conformity mark With this mark the manufacturer declares the compliance of the pr...

Страница 16: ...NDQ566_EN_V1 0_02 2021_IFU_CE MDR 16 4 5 Ambient conditions Operating conditions Temperature 0 C 40 C Charging conditions rechargeable battery 10 C 60 C Relative humidity non condensing 30 70 Air pre...

Страница 17: ...or using 4 screws 2 Press together the holder and slide the holding arm through the holder 3 Release the holder in the desired position The monitor is secured in place on the holding arm 5 3 Connectin...

Страница 18: ...using the swivel nut 3 Plug the power supply unit into the wall socket holding onto the plug housing not the cable itself The monitor is connected to the power supply The green indicator on the power...

Страница 19: ...kets concerned Adaptor for EUROPE Adaptor for UK Adaptor for USA Japan Adaptor for Australia IEC connection ROW Adaptor cable for USA Japan 5 4 Connecting a video unit The video unit connecting cable...

Страница 20: ...secondary camera s connector to the camera connection on the left housing side of the product 5 5 Connecting the external monitor The external monitor supports one of the following resolutions 1024 x...

Страница 21: ...be formatted on a PC with FAT standard The SD card has only one partition The C MAC monitor is switched off 1 Insert the SD card into the C MAC monitor in the correct position 2 Switch on the C MAC mo...

Страница 22: ...s bar Battery charge state Free memory capacity on the connected storage media SD card USB stick Secondary camera connection Progress bar Symbols on the status bar Symbol Meaning Connection of a secon...

Страница 23: ...iginal maxi mum capacity SD card storage capacity 100 of memory capacity available 75 of memory capacity available 50 of memory capacity available 25 of memory capacity available 0 of memory capacity...

Страница 24: ...rogress of the switch on procedure Shows the progress of the reset Shows the progress of the SD card formatting Shows the progress of emptying the trash Shows the progress of the data export to the US...

Страница 25: ...not possible Stop video recording Stops the video recording Video recording stops automatically under the following conditions The battery is empty The SD card is full The device has been switched to...

Страница 26: ...the list of saved video recordings Play Plays the selected video recording Pressing the control button switches to the level 2B functions Level 2B Delete Pressing the control button longer deletes th...

Страница 27: ...he next level You can move through sev eral levels by repeatedly pressing the menu wheel Wrench Back to level 1 Level 3 White balance Enables the user to run a manual white balance The progress bar in...

Страница 28: ...ion process Keep the button held down until the progress bar is complete Menu wheel Activates the functions of the next level You can move through several levels by repeatedly pressing the menu wheel...

Страница 29: ...g and confirm by pressing the arrow button Enter the month using and confirm by pressing the arrow button Enter the year using and confirm by pressing the arrow button Pressing the arrow button again...

Страница 30: ...product to restart Menu wheel Activates the functions of the next level You can move through several levels by repeatedly pressing the menu wheel Wrench Back to level 1 Level 9 Rotate image Rotates t...

Страница 31: ...B port serves exclusively to transfer data from the SD card to the USB stick Data cannot be saved directly to a connected USB stick Before use with the C MAC monitor the USB stick must be formatted on...

Страница 32: ...nitor to the power supply SD card full The SD card is full or write protected and will not allow any more data to be saved Remove the write protection or change the SD card No data can be saved to the...

Страница 33: ...he monitor to be quickly ready for operation again in the event of brief interruptions Press the On Off button briefly The green status LED flashes The monitor switches to standby mode After 5 minutes...

Страница 34: ...re in order a system error has occurred and a system reset must be carried out The reset switch is located in a recess to protect it from unintentional activation 1 Insert a ballpoint pen or similar i...

Страница 35: ...ed by KARL STORZ Regardless of the national accident prevention regulations and testing intervals for medical devices for this device safety checks must be performed as repeat inspections according to...

Страница 36: ...roduct meets the requirements of the Directive on Waste Electrical and Electronic Equipment WEEE Within the scope of application of this directive KARL STORZ SE Co KG is responsible for the proper dis...

Страница 37: ...monitors 8401ZX 8402ZX 8403ZX 8401YB Protective bag blue for C MAC system made from water resistant and hard wearing material washable separate compartments for monitor and three C MAC Video Laryn go...

Страница 38: ...004695 VESA 75 Quick Clip with 4 clamping screws for mounting C MAC to holding arms up to diameter 25 mm 8401YCA Exchangeable adaptors for charger Article Order no Adaptor for EUROPE ET27 30 0004697 A...

Страница 39: ...ic dis charge ESD acc to IEC 61000 4 2 8 kV contact dis charge 15 kV air discharge 8 kV contact dis charge 15 kV air discharge Floors should be made of wood concrete or covered with ceramic tiles If f...

Страница 40: ...test acc to IEC 61000 4 3 for radiated ra dio frequency electromagnetic fields 3 V m 80 MHz to 2 7 GHz Refer to Table 2 for wireless proximity RF field test levels 3 V m 80 MHz to 2 7 GHz Immunity to...

Страница 41: ...e in the electromagnetic environment specified below The user of the product should make sure that it is used in such an environment Interference immunity tests EN IEC 60601 test level Compliance leve...

Страница 42: ...fixed transmitters an electromagnetic site survey should be considered If the measured field strength at the location where the device is used exceeds the above compli ance levels the device should be...

Страница 43: ...ers and the product as recommended below according to the output energy of the communications equipment Rated power of the transmitter W Separation distance d m according to the transmitter frequency...

Страница 44: ...or similar Videoendoscope telescope is soiled Videoendoscope contacts are soiled Clean the videoendoscope telescope with a cotton swab and alcohol solution or special cleaning paste Clean videoendosco...

Страница 45: ...rite to the SD card SD card is formatted incorrectly SD card is write protected Format the SD card on the PC with FAT standard The SD card must have only one partition Remove the write protection on t...

Страница 46: ...RZ Endoscopy Suomi OY Taivaltie 5 01610 Vantaa Finland Phone 358 0 96824774 Fax 358 0 968247755 Email asiakaspalvelu karlstorz fi KARL STORZ SE Co KG Representation Office K stu io st 59 Lenktoji st 2...

Страница 47: ...ding B 18F Beijing IFC No 8 Jianguomenwai Street Chaoyang District 100022 Beijing People s Republic of China Phone 86 10 5638188 Fax 86 10 5638199 Email info karlstorz com cn KARL STORZ Endoscopy Shan...

Страница 48: ...RZ SE Co KG Dr Karl Storz Stra e 34 78532 Tuttlingen Postfach 230 78503 Tuttlingen Germany Phone 49 7461 708 0 Fax 49 7461 708 105 E mail info karlstorz com www karlstorz com NDQ566 EN V1 0 02 2021 IF...

Отзывы: