A90: Output connection relay K1 
A91: Output connection relay K2 

Generally, the outputs are exchangeable with parameter adjustments, in order to achieve an 
optimal relation of the existing hardware with regard to contact rating, kind of contact and number 
of cycles. Therefore, these parameters first assign the outputs to the controller function. 

 
Pro: Program version 

Indication of the program version. 
 

 
 
 
 
Status messages 
 
Message 

Cause 
 

Error elimination 

F1 

Sensor error 
(Short or open circuit at sensor F1, the 
buzzer sounds) 
 

Check sensor 
 

EP 

Data loss at parameter memory 
 

If error can not be eliminated by 
resetting the unit the controller 
must be repaired. 

“OIL” flashing, 
regulation runs 

Alarm message, caused by fat 
operation time exceeding (see P26) 

Delete with DWON key 

“OIL” flashing, 
regulation blocked 

Regulation blocking, caused by fat 
operation time exceeding (see P27) 

Delete with MELT + ON/OFF key 

“rES” 

Confirmation of the reset of the fat 
operating time 

 

"----" 

Key lock 
(see P19 and/or A19) 

----- 

Flashing display 

Boundary or range alarm 
(if activated, triggerd by temperature 
monitoring at sensor F1) 
 

----- 

Flashing point on 
the right 

Setpoint reduction activated 
(only with units with switching input)) 

----- 

Buzzer 

Temperature alarm (see A31) 

The buzzer can be stopped with 
the DOWN key. 

 
Error messages are saved and indicated even if the cause is eliminated. Pressing the DOWN key 
deletes the error message. 
 

Содержание 900219.092

Страница 1: ...ller and is cut to the use with deep fryers It has a 4 digit LED display 6 keys 2 relays and a switching input The different temperature setpoints and timer defaults can be parametered directly by the keys Sensor multi resistance input Range dependent on the type of sensor Front size 106mm x 68mm Panel cut out 87 5mm x 56 5mm Tightness front IP64 Connector screw terminal ...

Страница 2: ......

Страница 3: ...ivated with parameters The output relays are two change over contacts The functions heating control contact 2 or alarm can be assigned to each output even the deactivation of a output is possible The controller has the possibility of a particularly careful heating in case the deep fryer fat is not yet melted This retarded heating process Melt function is always activated after switching no the uni...

Страница 4: ...ing time is shown only for a moment but the flashing LED indicates the elapsing timer A permanent display of the remaining time can be activated with parameters then the LED of the timer is permanently on If the key is pressed for 5 seconds the timer is stopped and the display indicated 0 00 Key 3 4 setpoint reduction Simultaneously pressing these two keys activates the setpoint reduction in addit...

Страница 5: ...e OIL is deleted and if necessary the regulation blocking is cancelled The accumulated operating time is deleted Note that a reset is only possible in case of an alarm message or blocking and below the adjusted temperature limit value This is to prevent the user from operating the deep fryers without replacing the fat However an unconditional reset can be enabled by means of parameters ...

Страница 6: ...ing PID Turbo was possible the key now is ineffective 3 A6 1 A88 0 The melt function is deactivated and the PID control activated The controller has no reduced heating phase below the limit P37 In each case where switching Melt Turbo was possible it is now possible to switch between PID Turbo 4 A6 0 A88 0 Both the melt function and the PID control are deactivated The controller has no reduced heat...

Страница 7: ...ndicated by pressing keys 3 4 together By additionally pressing the UP or DOWN key it can be adjusted Para meter Function description Adjustment range Standard setting Custom setting S1 S2 S3 Temperature setpoints the currently selected setpoint is indicated and or adjusted P4 P5 C 170 C 160 C 100 C T1 Timer setpoint 0 00 99 99 Min 1 11 Min S1 Setpoint reduction is added to the main setpoint in ca...

Страница 8: ...0 C P5 Control range limitation maximum setpoint P4 999 9 C 205 C P7 Proportional band 1 100 K 10 0 K P8 Reset time Tn I factor 0 999 sec 0 sec inactive 0 sec P9 Lead time Tv D factor 0 999 sec 0 sec inactive 0 sec P10 Cycle time Tp 2 100 sec 10 sec P19 Key lock only for setpoint setting 0 no key lock 1 key lock 0 P20 Indication of actual value sensor F1 P21 Actual value correction sensor F1 20 20...

Страница 9: ... 2 Cooling controller symmetrical hysteresis The hysteresis is only effective if thermostatic mode is enabled in case of PID characteristic it is ineffective P4 Control range limitation minimum setpoint P5 Control range limitation maximum setpoint The adjustment range of the setpoint can be limited in both directions This is to prevent the end user of a unit from setting inadmissible or dangerous ...

Страница 10: ...ure limit for fat operating time Above this temperature the internal recording of fat operating time is started If the values of P26 and P27 are exceeded the alarm message and or regulation blocking is activated P26 Fat operating time until fat alarm message After this time period an alarm message requests the exchange of the deep frying fat The display indicates flashing OIL With P26 0 this funct...

Страница 11: ... boundary value Fig 5 Boundary alarm rel boundaries Range alarm function see fig 6 Opposite switching behaviour to the boundary value alarm The alarm contact is closed if the actual value remains between the boundary values Fig 6 Range alarm abs boundaries P32 Hysteresis alarm contact The hysteresis can be set symmetrically or one sided at the adjusted limit values see A42 It becomes effective dep...

Страница 12: ...1 cooling contact 0 A2 Switch mode contact K2 0 heating contact 1 cooling contact 0 A3 Function of contact K1 at sensor error 0 relay off 1 relay on 0 A4 Function of contact K2 at sensor error 0 relay off 1 relay on 0 A5 Selection setpoint 2 or DeltaW 0 operation with setpoint 2 1 operation with DeltaW 0 A6 Control characteristics contact K1 0 thermostatic 1 PID 0 A8 Display mode 0 integrals 1 res...

Страница 13: ...ff 0 0 99 0 sec 0 0 sec A56 Alarm suppression after mains on standby on 0 60 min 0 min A60 Sensor type 11 Pt100 2 wire 21 PTC 22 Pt1000 2 wire 11 A70 Software filter 1 not active or else 2 32 average value with 2 32 measuring values 2 A80 Temperature scale 0 Fahrenheit AUS 1 Celsius AUS 2 Fahrenheit OFF 3 Celsius OFF 3 A85 Reset mode of fat operation time 0 reset after alarm message or blocking an...

Страница 14: ...ontact K1 at sensor error A4 Function of contact K2 at sensor error At sensor error the selected relay falls back into the condition pre set here If there is a data loss in parameter memory display indicates EP both contacts K1 and K2 are switched off A5 Selection setpoint 2 or DeltaW This parameter determines whether the setpoints for thermostat 1 and 2 independently adjustable A5 0 or whether th...

Страница 15: ...e temperature lies beyond them In the case of sensor error the alarm is activated independently of this adjustment The output can be inverted to operate as a release A31 Special function at boundary or alarm Here can be selected whether in the case of an alarm the indication to flash and or the buzzer is to start Sensor alarm display F1L or F1H is indicated independently thereof by flashing displa...

Страница 16: ... This parameter can determine by how many measured values an average value is to be formed If a sensor with a very fast reaction to external influences is used an average value ensures a calm signal course A80 Temperature scale Indication can be switched between Fahrenheit and Celsius At conversion the parameters and setpoints maintain their numerical value and adjustment range Example A controlle...

Страница 17: ...eliminated by resetting the unit the controller must be repaired OIL flashing regulation runs Alarm message caused by fat operation time exceeding see P26 Delete with DWON key OIL flashing regulation blocked Regulation blocking caused by fat operation time exceeding see P27 Delete with MELT ON OFF key rES Confirmation of the reset of the fat operating time Key lock see P19 and or A19 Flashing disp...

Страница 18: ...r PTC Pt100 Measuring range PTC KTY81 121 50 C 130 C Pt100 80 C 400 C Accuracy 0 5K 0 5 at 25 C without sensor 1K 0 5 of scale range 0 55 C without sensor Outputs K1 Relay 10 1 5 A 250V change over contact K2 Relay 8 1 5 A 250V change over contact Summer ca 85dB Display One 4 digit LED Display height 13 mm colour red 6 LEDs for status display Power supply 230 V 50 60 Hz power consumption max 6 VA ...

Отзывы: