Adjustment options
Key 1: UP
Pressing this key you can increase the parameter or parameter value or scroll the
parameter list.
Key 2: DOWN
Pressing this key you can decrease the parameter or parameter value or scroll the
parameter list. At alarm the buzzer function can be switched off with this key. Any fat
alarm message can be switched off as well, however the internal alarm condition
remains active and the alarm restarts at each unit start.
Key 3: selection of temperature setpoint
With this key the temperature setpoint relevant for the regulation is selected. If
previously the timer display is active the controller at first switches to temperature
display with the first key pressing. With parameters you can determine if the respective
setpoint is still selected after switching of the mains voltage or if one of the setpoints
S1-S3 is selected.
Key 4: selection of timer setpoint
With this key the timer setpoint is selected and the LED of the timer lights up. The value
shows up in the display for 5 seconds and can be adjusted with the UP and DOWN key.
If none f the key is pressed the display automatically shows the temperature again, the
timer LED goes out. If the key is pressed for 2 seconds the timer is started and the LED
flashes. The remaining time is shown only for a moment but the flashing LED indicates
the elapsing timer. A permanent display of the remaining time can be activated with
parameters, then the LED of the timer is permanently on. If the key is pressed for 5
seconds the timer is stopped and the display indicated “0:00”.
Key 3+4: setpoint reduction
Simultaneously pressing these two keys activates the setpoint reduction, in addition
with the UP and DOWN key it can be adjusted. Please note that the setpoint reduction
is only effective in case of a closed switching input. In case of an activated setpoint
reduction a point flashes no the right side of the display. Setpoint reduction is only
possible with controllers with switching input(s).
Key
5: MELT/TURBO
With this toggle key one can choose between reduced and accelerated heating mode.
Together with the thermostatic function the turbo-heating offers a further increase of
heat supply. After switching on the controller the turbo-heating always is deactivated.
The key is ineffective if the reduced heating mode is deactivated or in some
temperature ranges if no PID characteristic is selected. See below for all choice
options.
Key 6: ON/OFF
If this key is pressed for 1 second the controller switches to standby mode, the display
shows “OFF” or “AUS” and a started timer cycle is aborted. After switching mains on the
controller always is in standby mode. The key can be deactivated, then the controller is
switched on with mains voltage.