Stonex S990A GNSS Receiver – User Manual v1.0
38
8.1.2
Initialization
After the activation of the sensor, go in Survey mode.
If the sensor is not ready to work yet, Cube-a will show you which operations
are necessary to perform its initialization.
There is a necessary pre-requisite to use the IMU: the status of the GNSS
solution must be
Fixed
(Fixed, aRTK Fixed, Surefixed or ExtraSafe Fixed).
When, and only when, the receiver is in Fixed
, and
if the sensor needs to
be initialized
, two different popup screens could show up.
The first screen shows up seldomly: it lets the sensor adjust for the local
magnetic field. Just rotate the pole with the device as shown in the picture
below.
The second screen lets the sensor adjust the calibration parameters based on
the local GNSS position and accuracy.