- 16 -
OPERATION
95CMP & 95CMPED
CAPACITIES
* Maximum batch size depends on mix and type
of aggregate used.
SAMPLE MIX
Volume relationship of 1:2-1/4:3
(cement : sand : gravel) mix. The mix volume may
vary depending on aggregate used.
CLEANING
For consistent performance, long life and continued
high quality mixing of cement, thoroughly clean the
mixer inside and out at the end of each day's operation.
Drum may be scoured by 2 minute operation with
gravel and water mixture. Discharge, then hose down
drum inside and outside. Keep mixer clean.
Before cleaning, shut the engine or motor and
disconnect the spark plug wire or electric cord to
prevent accidental starting. Spray the mixer with water
before the mix dries to remove any accumulations.
Dried mix should be scraped out as necessary.
NEVER POUR OR SPRAY WATER OVER THE
ENGINE OR MOTOR.
NEVER PUT HANDS OR ANY OBJECT INTO
THE DRUM WHILE THE ENGINE OR MOTOR
IS RUNNING.
ALWAYS DISCONNECT THE SPARK PLUG
WIRE OR ELECTRIC CORD WHEN CLEANING
INSIDE DRUM.
TOWING
Before attempting to tow this mixer, check the state
and local laws that apply to your intended route and
check the following:
1. Hitch attached to the towing vehicle
securely.
2. Towpole fully extended and bolted to mixer
securely.
3. Safety chain hooked up properly (see
illustration below or decal on mixer front post).
95CMP
95CMPED
Total Drum
Volume
15.1 cu. ft.
15.1 cu. ft.
Max. Batch
Size*
9.0 cu. ft.
9.0 cu. ft.
WARNING
Mix Volume
Cu. Ft.
3
4
6
9
Cement
(bags)
1/2
2/3
1
1-1/2
Water (gal.)
2-1/2
3-1/2
5-1/4 8
Sand (gal./
shovels)
9
12
18
18
Gravel (gal./
shovels)
12
16
23
23
Содержание 95CMP