Figure 1 – Basic Overall Dimensions including spacer hanging bracket 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Technical Data 
 

General Data 
 
Maximum Pressure – District 

 

 

 

 

 

6 bar 

Maximum Pressure – Heating 

 

 

 

 

 

3 bar 

Maximum District Temperature   

 

 

 

 

85°C 

Maximum District Flow Rate 

 

 

 

 

 

18l/min 

 
Weight Empty 

 

 

 

 

 

 

 

20 kg 

Dimensions   

 

 

 

 

 

 

 

469 x 630 x 276 

 
Electrical Supply 

 

 

 

 

 

 

 

230V – 3 Amp 

Power Consumption 

 

 

 

 

 

 

105W 

 

 

Содержание ECONOPLATE H1

Страница 1: ...LLING COMMISSIONING OPERATING OR SERVICING EQUIPMENT THE ECONOPLATE H1 UNIT IS INTENDED FOR USE IN LOW TEMPERATURE DISTRICT HEATING SCHEMES STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY K...

Страница 2: ...HEAT INTERFACE UNIT COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE LOW VOLTAGE DIRECTIVE 2006 95 EC AND THE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2004 108 EC 1 WARNINGS Inside the Unit there is 230...

Страница 3: ...egulations 3 UNIT DESCRIPTION This Heat Interface Unit is designed to be used on low temperature hot water supply of up to 85 C The Unit is configured to provide indirect heating to a heating system v...

Страница 4: ...nging bracket Technical Data General Data Maximum Pressure District 6 bar Maximum Pressure Heating 3 bar Maximum District Temperature 85 C Maximum District Flow Rate 18l min Weight Empty 20 kg Dimensi...

Страница 5: ...3 4 BSP Male Heating Inlet Outlet 3 4 BSP Male Heating Performance Heat Output t 11K Heating Circuit 22kW XS Head from Integral Pump t 11K 22kPa Min System Features Heating Ramp Up Time of 3 Minutes P...

Страница 6: ...need access from above and below the Unit to install the relevant Pipework to and from the Unit A spacer plate has been provided enabling pipework to be run behind the Unit Secure the spacer plate to...

Страница 7: ...ave been properly flushed out Figure 4 Pipework Connections District Inlet and Outlet Male BSP These are situated at the top of the unit with inlet on the left Connection 1 Figure 5 and outlet on the...

Страница 8: ...leave the unit Water Inlet capped off This connection is here should the system ever be converted to unvented It has been capped off both ends to indicate it is not in use and so nothing should be co...

Страница 9: ...the Unit is ready for its operation When the switched live is activated by a requirement from your system the Unit will activate Heating mode after approx 5 seconds The system Pump will be switched on...

Страница 10: ...e Appendices Table 1 If the above does not rectify the problem and the Unit still does not operate satisfactorily then below are some suggestions of potential issues Alternatively consult Supplier for...

Страница 11: ...fouled 9 SERVICING SCHEDULE Note when working with the unit supply services when connected could reach 85 C and once electrically connected the unit has 230V present within It is recommended that this...

Страница 12: ...11 10 INTERNAL COMPONENTS Figure 9 Internal Components...

Страница 13: ...12 11 UNIT SCHEMATIC...

Страница 14: ...ack Not used connected together Table 2 Electronic Box Dip Switches SWITCH FUNCTION ON OFF 1 High temp Low temp central heating Low temp High temp 2 H1 Heating only Heating only needs DIP switch 4 on...

Страница 15: ...14 Table 4 Pump Data...

Отзывы: