background image

PREVENTATIVE MAINTENANCE 

Stoelting recommends following this preventative maintenance schedule to keep the freezer clean and operating 
properly. 

WEEKLY 

 

CLEAN INSIDE OF FREEZER 

Remove all side panels and clean the inside of the freezer. Wipe any custard that may have dripped onto 
the inner panels with a damp soapy towel. Wash the drain tray. 

 

CLEAN REAR SHAFT SUPPORT BUSHING 

Remove the rear support bushing by unscrewing it. Remove the o-ring and examine it. Replace the o-ring 
if it is cracked or worn. Wash the bushing and lubricate the o-ring with Petrol-Gel. 

 

CHECK FOR SHAFT ALIGNMENT 

It is important to keep the auger shaft aligned at all times. There are a few early indications that the shaft 
is out of alignment. Make sure there are no metal shavings under the bearing. Inspect the rear coupling 
for wear. Check the front door plate for wear from the front bushing. If the shaft is out of alignment, the 
freezer may be making a lot of noise. 

Contact Stoelting Customer Service for an alignment kit if you suspect that the auger shaft is out of 
alignment. 

QUARTERLY 

 

REPLACE BARREL PARTS 

Follow the Parts Replacement Schedule to keep the freezer operating properly. 

 

CLEAN CONDENSER COILS (AND FILTERS IF APPLICABLE) 

The coils on the hopper, dipping cabinet and remote condenser need to be cleaned to ensure proper 
airflow. Use compressed air to clean the condensers. Blow the air in the opposite direction of the normal 
airflow. If the condenser has a filter, remove it and vacuum or brush clean. Rinse the filter with clean 
water and allow it to dry before replacing it on the condenser. 

ANNUALLY 

 

REPLACE BARREL PARTS ACCORDING TO REPLACEMENT SCHEDULE 

Follow the Parts Replacement Schedule to keep the freezer operating properly. 

 

DRIVE BELT WEAR AND TENSION 

Inspect the drive belts for wear. Check for wear marks from the belts rubbing on the pulley. 

Press firmly on the belts. When tension is properly adjusted, the belt will depress the approximate width 
of the belt with the pressure of a finger. If an adjustment is necessary, loosen the bolts holding the motor 
to the frame and push the motor downward. Use a 5’ long 2x4 as a lever to get the proper tension, and 
then tighten the bolts. 

 

LUBRICATE BEARINGS AND MOTORS 

The pillow block bearings and the motors have grease fittings. Use a grease gun with Shell Alvania RL2, 
Texaco Multifak 2, or equivalent as lubrication. Add enough grease on the bearings so that a small 
amount appears on the drive shaft. The motor requires a small amount of grease. Apply one compression 
of the grease gun to the grease fitting on the motor. Wipe all fittings clean after lubricating. 

Содержание Ross CC303-209A00SIR

Страница 1: ...Model CC303W OPERATING MANUAL Manual No 513621 Rev 5...

Страница 2: ......

Страница 3: ...tremely important that the following instructions be followed exactly each time the machine is disassembled for cleaning as part of nightly shutdown procedures Ross s makes no warranties expressed or...

Страница 4: ...942 625140 C 9000 58 C 2000 81 C 2000 56 C 2000 51 C 2000 50 RG 0020 SL 0010 2187605 674187 C 4000 14 360004 SV OF 0020 SV C 4000 20 C 4000 19 C 2000 61 CA 0010 CA 0020 C 2000 57 C 4000 15 C74 BR 0020...

Страница 5: ...C 2000 40 Bushing Auger Shaft 1 C 2000 50 Spring 12 C 2000 51 Blade 12 C 2000 52 SV Plate Front w Stainless Steel Insert 1 C 2000 56 Gate Front 1 C 2000 81 Rod Flow Control 1 C 4000 20 Slide Short Ch...

Страница 6: ...it bumps against the square of the shaft Put a small amount of Hex Drive Anti Seize on the hex end of the beater shaft 2 Starting on the end of the beater shaft with the square tip place a metal sprin...

Страница 7: ...of the machine is turned OFF the front control knob is to be in the OFF position 2 Remove the front gate and replace with splash guard Secure with wing nut The splashguard di rects the water into the...

Страница 8: ...exture Note If a growling noise comes from the machine during this procedure it may be an indication that there is not enough mix entering the barrel In crease the flow slightly by adjusting the flow...

Страница 9: ...t for approx 20 minutes This al lows the barrel enough time to warm before drain ing the remaining mix from the hopper 3 Take a sanitized bucket and place it at the opening of the front plate 4 Turn t...

Страница 10: ...nstalled into the same barrel every time the ma chine is disassembled 1 Remove key 2 Remove the front gate and front plate for washing Remove the o ring from the front plate Remove front bushing from...

Страница 11: ...tard is used 12 Return to the sink and wash each part Place in a rinse tank and then a sanitizing tank with a proper dilution of an approved sanitizer Cleaning and Disassembly NEVER USE HOT WATER ANY...

Страница 12: ......

Страница 13: ...are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Checklist Warranty Registration Card for the affected equipment b gives Stoelting prompt written notice...

Страница 14: ...001 1332808 2...

Страница 15: ...s when installing line sets Seal the ends of the line sets during installation to prevent exposure to the atmosphere and foreign objects Blow the lines out with dry nitrogen to remove any debris that...

Страница 16: ...ale connector is 1 4 OD Solder a 5 16 line to the water valve inlet using silver solder the M202 requires a 1 4 line Install a shutoff valve in the water inlet line The drain connection is 1 1 2 Run a...

Страница 17: ...gram 6 Use an Allen wrench to open the shut off valves and release some of the nitrogen charge in the condensing unit The shut off valves are located on the outside of the condensing unit If no nitrog...

Страница 18: ...sters will be in a box located in the hopper pan A set of casters includes two casters with locks and two casters without locks Screw the casters into the threaded holes and tighten them using a pair...

Страница 19: ...1 and T3 output leads going to the motor from the drive C Change the leads inside the motor electrical box 6 Check the refrigeration systems for leaks When pressurizing the system turn the refrigerati...

Страница 20: ...e crankcase pressure regulator CPR if the pressure is not correct Remove threaded brass cap on the front of the CPR and adjust the valve with a 5 16 Allen wrench Connect a gauge to the suction line at...

Страница 21: ...er for the condensing unit 4 The refrigeration system for that barrel is set to warm for the mix Contact Ross service department and a technician can help adjust system properly 5 Condenser on remote...

Страница 22: ...ed in hopper is too warm 1 Make sure the hopper switch is on 2 Ranco temperature control located on the service side of the machine is set to warm Refer to the operating manual for proper settings 3 I...

Страница 23: ...d to check that the breaker for that outlet has not tripped If the breaker has tripped then reset and check dipping cabinet if it is running 2 Check condenser coil and make sure not plugged with dust...

Страница 24: ......

Страница 25: ..._______ Diff 1 degree ________ Mode CL ________ Hold Cycle Temperature Control Location within Machinery Electrical Box Note Temperature setting may be adjusted for your particular settings Option 1 I...

Страница 26: ...ed firmness Automatic Expansion Valve Original Factory Setting 25 PSIG Typical pressure setting for most custard mixes 32 PSIG Your final valve ________ Note each machine will differ slightly in prefe...

Страница 27: ...APPLICABLE The coils on the hopper dipping cabinet and remote condenser need to be cleaned to ensure proper airflow Use compressed air to clean the condensers Blow the air in the opposite direction of...

Страница 28: ......

Страница 29: ...Front Wear Bushing X 3 C 2000 67 Large O Ring X 3 RG 0010 Medium O Ring X 3 RG 0020 Double Lip Shaft Seal X 3 SL 0010 KO Dirt Blaster Condenser Cleaner X 1 BL 0030 Blades X 36 C 2000 51 To order the r...

Страница 30: ......

Страница 31: ...ectrical Schematic Pilot Light HOPPER OS CC WHT WHT WHT RED BLK Hopper Temperature Control 120V COM NO C BLU BLU Pressure Switch YEL GRN Receptacle For Condensing Unit BLK BLU BRN WHT GRN 115 Volt 15...

Страница 32: ...atic HOPPER OS CC R 134A Compressor Evaporator Hopper Pan Air Cooled Condenser Low Pressure Switch Open 5 PSIG Close 20 PSIG Dryer Filter L Shut off Valve P 1 4 Capillary Tube 3 8 BC 2 8 High Pressure...

Страница 33: ...ustable High Pressure Switch Open 400 PSIG Close 320 PSIG Low Pressure Guage Heat Exchanger High Pressure Tap Head Pressure Auto Expansion Valve Set at Approximately 28 32 PSIG Lemon Ice Option Set at...

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ...ater lines flushed before connection W C Checked pressures on high side suction side and barrel Proper water and drain size W C Refrigeration level during operation clear sight glass Proper clearance...

Отзывы: