background image

 

 

DOMESTIC WARRANTY 

 

 

(Including Mexico) 

 
 
 

Page 2 of 2 

SFWARR-013 Revision 10 

5. 

Conditions: 

a)  If the date of the original installation cannot be verified, these warranty periods begin one (1) year from the shipping date. It is 

the responsibility of the seller to disclose this information to the Buyer at the time of sale. 

b)  Stoelting shall not be responsible to provide any remedy under this warranty with respect to any component that fails by reason 

of negligence, abnormal use, misuse or abuse, faulty repair made by others, use with parts or equipment not manufactured or 
supplied by Stoelting, any modification or alteration of any parts or equipment, or damage in transit. 

c)  This warranty is valid only if the Equipment is installed and serviced by an Authorized Stoelting Provider and only if new, genuine 

Stoelting parts are used. 

d)  The Equipment installation location must have suitable conditions as explained in the Stoelting operators manual, specification 

sheet, and/or technical manual including but not limited to, ambient temperature, water supply parameters, and space 
requirements. 

e)  The Authorized Stoelting Provider must return defective parts, at Stoelting’s discretion, for credit. 

f) 

Any refrigerant other than that specified on the Equipment model identification nameplate voids this warranty. 

6. 

Exceptions: 

 

This warranty does 

NOT

 cover any of the following  

 

a)  Costs associated with installation labor, disposal of equipment being replaced, and shipping costs of replacement parts or 

Equipment. 

b)  Cleaning, maintenance or lubrication of the Equipment as outlined in the Stoelting operators manual. 

c) 

This warranty does not extend to parts, sometimes called “wear parts”, which are generally expected to deteriorate and to require 
replacement as equipment is used, including but limited to o-rings, auger flights, auger seals, auger support bushings, and drive 
belts. All such parts are sold 

AS IS. 

d)  External components including but not limited to hoses, piping, or electrical equipment. 

e)  Labor and travel charges due to return trips or waiting if the Authorized Stoelting Provider is prevented from promptly starting 

service work upon arrival. This exception includes labor charges incurred for limited access facilities including, but not limited to, 
government and military buildings, and airports. 

f) 

Failure, damage, or repairs due to faulty installation, misapplication, abuse, lack of service, or improper service, unauthorized 
alteration, improper operation as indicated in the Stoelting operators manual, including but not limited to failure to properly 
assemble and/or clean, improper tool usage, or use of unapproved lubrication, or cleaning and sanitizing supplies. 

g)  Any costs associated with electricity, including utility increases, from any reason whatsoever. 

h)  Damage resulting from the use of refrigerant other than that specified on the Equipment model identification nameplate. 

i) 

The use of this equipment as a rental asset negates all warranties associated with the equipment. 

j) 

Any special, indirect or consequential property or commercial damage of any nature whatsoever, if the jurisdiction allows this 
exclusion. 

k)  Costs not covered by the Stoelting Travel Pay policy. Stoelting covers only the first trip travel which is a flat rate by mileage one-

way from the service company’s home location to the job site. The flat rate is calculated as follows: 

o

 0-50 

Miles 

$85 

o

 51-110 

Miles  $127 

o

 111-160 

Miles  $165 

o

 

Over 160 Miles 

The maximum reimbursed by Stoelting is $165 

Any travel costs not covered may be invoiced to the customer. 

7. 

Limitations: 

 
 

THE REMEDIES SET FORTH IN THIS WARRANTY SHALL BE THE SOLE LIABILITY STOELTING AND THE 
EXCLUSIVE REMEDY OF BUYER WITH RESPECT TO EQUIPMENT SUPPLIED BY STOELTING; AND IN NO 
EVENT SHALL STOELTING BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING 
AS EXAMPLES BUT NOT INTENDED TO BE LIMITED TO DOWNTIME, OVERHEAD, MATERIALS, 
PERFORMANCE PENALTIES, LOST SALES, LOST PROFITS, PRODUCT LOSS, OR PROPERTY DAMAGES, 
WHETHER FOR BREACH OF WARRANTY OR OTHER CONTRACT BREACH, NEGLIGENCE OR OTHER TORT, 
OR ON ANY STRICT LIABILITY THEORY. 

Содержание IntelliTec M202 series

Страница 1: ...Model M202 IntelliTec OPERATORS MANUAL Manual No 513666 Rev 2...

Страница 2: ......

Страница 3: ...w parts for machines built prior to date of change DO NOT ATTEMPT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood If p...

Страница 4: ...t specific safety information the following safety defini tions are provided to assist the reader The purpose of safety symbols is to attract your at tention to possible dangers The safety symbols and...

Страница 5: ...tial Set Up and Operation 3 1 Operator s Safety Precautions 9 3 2 Operating Controls and Indicators 9 3 3 Sanitizing 10 3 4 Freeze Down and Operation 11 3 5 Mix Information 12 3 6 Removing Mix from Ma...

Страница 6: ......

Страница 7: ...d to assist qualified service personnel and operators in the installation operation and mainte nance of the M202 frozen custard machine NOTE Product breakdown could happen quicker if product is stored...

Страница 8: ...sides and 24 60 9 cm at the back They are charged with R 404A Air cooled units require one remote condensing unit with compressor per barrel Condensing units 285090 and 285091 ship from the factory w...

Страница 9: ...apping on the machine Remove the lower front and back panel on the machine F Remove the four lag bolts located inside machine on the frame with a 9 16 ratchet Remove the two lag bolts that hold the sk...

Страница 10: ...ach freezing cylinder 2 The electrical boxes are located behind the lower front panel Labels indicate which cylinder each electrical box powers No pigtails are supplied with the machine or condensing...

Страница 11: ...requirements for roof installations Allow at least 3 feet of clearance on the air intake and discharge sides of the condensers Do not set the condensers so that one is blowing air directly into the ot...

Страница 12: ...t with compressor per barrel Condensing units 285090 and 285091 ship from the factory with 20 lbs of R 404A for up to a 50 line set Add 1 lb of refrigerant for every 10 increase to the line set Line s...

Страница 13: ...psi Custard mixes that use an extract flavoring will run differently Try different pressure settings by adjust ing the AXV Adjust the pressure setting between 28 32 psi the machine will not operate co...

Страница 14: ...Owner s Manual 513666 8 M202B Model Machines...

Страница 15: ...nected G Donotoperateunderunsafeoperatingconditions Neveroperatethemachineifunusualorexcessive noise or vibration occurs 3 2 OPERATING CONTROLS AND INDICATORS Before operating the machine it is requir...

Страница 16: ...e auger willcontinuetorotateandhopperrefrigerationwill stop F Mix Low Light Indicator The MIX LOW message will appear on the LCD display to alert the operator to a low mix condition The message will d...

Страница 17: ...osition D Place a bucket under the slide E Pour the sanitizer into the hopper NOTE A small amount of sanitizer may drain into the bucket with the flow control shut and may seep out of the rear seal F...

Страница 18: ...checking the tem perature stir the thermometer in the frozen product to read the true temperature Old mix or mix that has been stored at elevated tempera tures will produce poor quality product with...

Страница 19: ...en the water has drained place the switch in the OFF position Allow the freezing cylinder to drain completely E Prepare Stera Sheen or equivalent cleaner in 2 gallons of 90 to 110 F 32 to 43 C water f...

Страница 20: ...parts should be replaced to ensure safety to both the operator and the customer and to maintain good machine performance and a quality Lubricate Back End of the Auger Lubricate the rear of the auger...

Страница 21: ...for storage of the machine over any long shutdown period A Turn the Freezing Cylinder OFF ON switch to the OFF position B Disconnect unplug from the electrical supply source C Clean thoroughly with a...

Страница 22: ...Owner s Manual 513666 16 M202B Model Machines...

Страница 23: ...f the cutout value is not attained during Standby Mode or if the Ready signal does not come on in Custard Mode or Italian Ice Mode This error is generally caused by very low mix levels in the hopper o...

Страница 24: ...r air clearance around the condenser In a water cooled machine check that the water is not shut off If the error persists contact your Authorized Stoelting Distributor for further assistance Error Cod...

Страница 25: ...mix 2 Call Stoelting service department and we can help over the phone to adjust setting properly 3 Air flow to condenser is blocked 3 Check for blockage and clean if necessary 4 Water cooled machine...

Страница 26: ...Owner s Manual 513666 20 M202B Model Machines...

Страница 27: ...al Wiring Materials 324141 Decal Caution Rotating Blades 324208 Decal Attention Refrigerant Leak Check 324346 Decal Caution Hazardous Moving Parts 324509 Decal Cleaning Instructions 324548 Decal Adequ...

Страница 28: ...00 20 Slide Short Chute 1 NT 0010 Wing Nut Stainless Steel 1 per barrel SL 0010 Seal Beater Shaft 1 per barrel 149014 Bushing Front Auger Support 1 per barrel 336588 Face Plate 1 per barrel 482055 Kno...

Страница 29: ...Machines Part Description Quantity 754021 Tube Flow Control Hopper 1 per barrel 2202565 Tray Drain 1 2202588 Cover w Handle Hopper 1 per barrel 2203311 SV Flow Control Rod 1 per barrel 5 1 HOPPER PAR...

Страница 30: ...Owner s Manual 513666 24 M202B Model Machines...

Страница 31: ...se obligations remedies are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Start Up and Training Checklist for the affected equipment b gives Stoelting pro...

Страница 32: ...ed to hoses piping or electrical equipment e Labor and travel charges due to return trips or waiting if the Authorized Stoelting Provider is prevented from promptly starting service work upon arrival...

Отзывы: