18

D.  QUARTERLY

WARNING

High voltage will shock, burn or cause death. Turn
off and lock out main power disconnect before
servicing. Do not operate machine with cabinet
panels removed.

The air-cooled condenser is a copper tube and aluminum
fin type. Condensing is totally dependent upon airflow. A
plugged condenser filter, condenser, or restrictions in the
louvered panel will restrict airflow. This will lower the
capacity of the system and damage the compressor.

The condenser must be kept clean of dirt and grease. The
freezer must have a minimum of 3” (7.5 cm) of ventilation
on the right and left sides of the unit for free flow of air
(Figure 29). Make sure the freezer is not pulling over 100°
F (37° C) air from other equipment in the area.

The water-cooled condenser is a tube and shell type. The
condenser needs a cool, clean supply of water to properly
cool the freezer, inlet and discharge lines must be 3/8” I.D.
minimum.

The condenser and condenser filter require periodic
cleaning. To clean, refer to the following procedures.

1. Remove the Phillips head screw from the bottom of

the right side panel, and then slide the panels down
and out.

2. To remove the condenser filter, grasp the top and pull

off. Visually inspect for dirt. If the filter is dirty, shake
or brush excess dirt off the filter and wash in warm,
soapy water. Once the filter is clean rinse thoroughly
in warm, clear water and shake dry, taking care not
to damage the filter in any way Figure 29).

3. Visually inspect the condenser for dirt by shining a

light through the coil from the back (inside) of the
condenser.

4. If the condenser is dirty, place a wet towel over the

front (outside) of the condenser.

5. Using a vacuum, carefully clean the condenser coil

from the inside and outside of the freezer. A stiff
bristled brush may help in releasing debris from
between the condenser coils.

NOTE

If the condenser is not kept clean, loss of refrig-
eration efficiency will result; causing extended run
time or soft product consistency.

Water-cooled condensers need an unrestricted supply
of cold, clean water.

Figure 29.  Condenser and Filter

Figure 30.  Cleaning Condenser

Содержание Futura F131

Страница 1: ...Futura F144 and F131 w Blender OWNER S MANUAL Manual No 513603 1 March 2005...

Страница 2: ......

Страница 3: ...are certified in the Stoelting Technicare program Model No _______________________ Serial No _______________________ Purchase Date ____________________ Start Up Date ____________________ CALL Distrib...

Страница 4: ......

Страница 5: ...new parts for freezers built prior to date of change DO NOT ATTEMPT to operate the freezer until instructions and safety precautions in this manual are read completely and are thoroughly understood If...

Страница 6: ......

Страница 7: ...light specific safety information the following safety definitions are provided to assist the reader The purpose of safety symbols is to attract your attention to possible dangers The safety symbols a...

Страница 8: ......

Страница 9: ...Operating Controls and Indicators 7 3 3 Sanitizing 9 3 4 Freeze Down and Operation 10 3 5 Mix Information 11 3 6 Removing Mix from Freezer 11 3 7 Cleaning the Freezer 12 3 8 Disassembly of Freezer Pa...

Страница 10: ...tion Draining 10 15 SanitizingAgitator Shaft 10 16 Dispensing Product 11 17 Removing Mix Inlet Regulator 11 18 Draining Mix 12 19 CleaningAgitator Shaft 12 20 Auger Flight Wear and Front Auger Support...

Страница 11: ...ightspigot withtheconvenienceandcost of one unit The freezer is designed to be used with both barrels in operation If you desire to use one barrel only thefreezermustbecleaned sanitizedandfilledwithfr...

Страница 12: ...s 20 Amp maximum fuse or circuit breakers NEMA 6 20P power cord provided Automatic safeguard circuit built into electronic control protects major freezer components under normal operating conditions R...

Страница 13: ...intain a safe working environment The labels have been designed to withstand washing and cleaning All labels must remain legible for the life of the freezer Fig 3 Warning Label Locations Labels should...

Страница 14: ...nt is necessary level the freezer by turning the bottom part of each leg in or out Then separate freezer base gasket and install with the seam to the back and the flat to the bottom C Air cooled freez...

Страница 15: ...t of the freezer to the door end of the stand Secure the freezer to the stand with the nuts and lock washers provided Then separate freezer base gasket and install the seam to the back and the flat to...

Страница 16: ...6...

Страница 17: ...electrical power has been disconnected SECTION 3 INITIAL SET UP AND OPERATION G Do not operate under unsafe operating condi tions Never operate the freezer if unusual or exces sive noise or vibration...

Страница 18: ...green light illuminates before dispens ing E CLEAN SWITCH TheCLEANswitchisa snap switch Whentheswitch is pushed the refrigeration system will be OFF and the auger will rotate for cleaning When the swi...

Страница 19: ...MENT BE CERTIFIED FOR THIS USE When sanitizing the freezer refer to local sanitary regulations for applicable codes and recommended sanitizing products and procedures The frequency of sanitizing must...

Страница 20: ...e top of the air inlet tube on the mix inlet regulator E The freezer barrel will automatically fill until it is about 1 2 full If freezer barrel does not fill check for obstruction in the mix inlet re...

Страница 21: ...al State and local regulatory agencies Figure 16 Dispensing Product 3 5 MIX INFORMATION Mix can vary considerably from one manufacturer to another Differences in the amount of butterfat content and qu...

Страница 22: ...er When the water has drained turn the OFF ON switch to the OFF position Allow the freezer barrel to drain completely CAUTION Hazardous Moving Parts Revolving blender agitator shaft can grab and cause...

Страница 23: ...s Fig 21 Figure 21 Removing Front Door C Remove the rosette caps from the front door Push the spigot body through the bottom of the front door and remove Fig 22 Figure 22 Front Door Disassembly D Remo...

Страница 24: ...remove and let air dry C Using this sanitizing solution and the large barrel brush provided sanitize the rear of the barrel and drive area by dipping the brush in the sanitizing solution and brushing...

Страница 25: ...he surface of the cam on the spigot handle prior to assembly of handle to the spigot body H Install the spigot bodies with O rings into the front door from the bottom Fig 27 Push straight up until the...

Страница 26: ...g efforts within a layer of soil material milkstone Thorough cleaningproceduresthatinvolvemilkstone removal are critical for operators of frozen dessertmachines SANITIZING Kills bacteria Can be effect...

Страница 27: ...the ability to remove milkstone Milkstone will become a problem if not remedied with additional products and procedures THE USE OF CHLORINE TEST STRIPS Test strips are used to determine concentration...

Страница 28: ...ire periodic cleaning To clean refer to the following procedures 1 Remove the Phillips head screw from the bottom of the right side panel and then slide the panels down and out 2 To remove the condens...

Страница 29: ......

Страница 30: ...20...

Страница 31: ...t s u j d a e R 3 e c i v r e s r o f r o t u b i r t s i d l l a C e c a l p e R 4 r o f r o t u b i r t s i d l l a C m e t s y s k c e h C 5 e c i v r e s o o t s i t c u d o r P t f o s n e h w d...

Страница 32: ...t r i a r o t a l u g e r t e l n i x i M 4 d e k c o l b n w o d k a e r b t c u d o r P 5 e z e e r f d n a e z i t i n a s n a e l c x i m e v o m e R 1 x i m h s e r f h t i w n w o d r o t a l u...

Страница 33: ...te timer will not time out A flashing clean light is not an error NOTE Flashing CLEAN light is not an error It indicates the freezer is in the CLEAN mode To exit turn the OFF ON switch to the OFF posi...

Страница 34: ...24...

Страница 35: ...5 5 8 ID x 1 8 CS Front Door 1 625133 4 ID x 3 16 CS O rings are drawn to Approximate Size Rear Seal 1 624678 5 1 1 8 ID x 3 16 CS Part Number Description Part Number Description 208135 Brush Nylon 16...

Страница 36: ...uger Spring 8 10 624677 5 O ring Mix Inlet Regulator and Spigot Extension 5 Pack 6 11 3170644 Front Auger Support 2 12 149003 Auger Bushing 2 13 4157968 Auger Shaft 2 14 624678 O ring Auger Shaft Seal...

Страница 37: ...es are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Checklist Warranty Registration Card for the affected equipment b gives Stoelting prompt written noti...

Отзывы: