background image

17

3.

SANITIZING

 – After the machine has been

cleaned and contains no milkstone, the
machine is reassembled.  Then a FDA approved
sanitizing solution is run through the machine to
kill bacteria.  The machine is then ready for
food preparation.

As a recommended cleaner and sanitizer for your
frozen dessert machine, STERA-SHEEN has proven
to be one of the best daily maintenance products for:

·

CLEANING

 – Thorough removal of all solids

including butterfat and milk fat.

·

MILKSTONE REMOVAL

 – Complete removal of

milkstone.

·

SANITIZING

 – FDA-approved no rinse sanitizer

for food contact surfaces.

Additional Information

THE USE OF DELIMERS

A delimer is a strong acid that has the ability to
dissolve milkstone.  This type of chemical may
become necessary once high levels of milkstone
have developed.  While these products are very
effective for removing HIGH levels of milkstone, they
are not ideal for two reasons:

1.

PRODUCT SAFETY

 – Strong acids are

dangerous chemicals and handling them
requires safety

2.

MACHINE DAMAGE

 – Strong acids will attack

metal and rubber causing premature wear of
parts.  The use of a delimer needs to be closely
monitored to avoid damage to machine surfaces
and parts.

With proper daily use of STERA-SHEEN or it’s
equivalent, there is 

no need

 for the use of a

DELIMER

.

DO NOT USE BLEACH

·

BLEACH HAS ABSOLUTELY 

NO

 CLEANING

PROPERTIES.

·

BLEACH IS CORROSIVE.  It can and will
damage components of the machine causing
premature wear and metal corrosion.

GENERAL PURPOSE CLEANERS

General purpose cleaners 

do

 

not

 have the ability to

remove milkstone.  Milkstone will become a problem

if not remedied

 with additional products and

procedures.

THE USE OF CHLORINE TEST STRIPS

“Test strips” are used to determine concentrations of
active chlorine in sanitizing solutions.  To use the
strips, tear off a small portion and submerge it into
the sanitizing solution.  Then, compare the color
change to the color key on the side of the test strip
dispenser to determine the approximate chlorine
concentration.

The ideal concentration of chlorine needs to be 100
ppm (as stated by the FDA).

NOTE

Follow the directions on the container for proper
concentration.

There are two main factors that contribute to falling
chlorine concentrations in a sanitizing solution.

1.

PRODUCT USE

 – As the chlorine in the

solution is being used, chlorine concentrations
fall.

2.

TIME

 – As time passes, small amounts of

chlorine “evaporate” from the solution.  (That is

why you can smell it.)

Sanitizing solutions 

should

 

not

 be allowed to fall

below 100 ppm chlorine.  New solutions should be
mixed once old solutions become ineffective

B. DAILY

1.

The exterior should be kept clean at all times to
preserve the lustre of the stainless steel. A mild
alkaline cleaner is recommended. Use a soft
cloth or sponge to apply the cleaner.

CAUTION

Do not use acidic cleansers, stron caustic com-
pounds or abrasive materials to clean any part of
the freezer exterior or plastic parts. Use of these
types of cleaners will cause equipment damage.

C. WEEKLY

1.

Check O-rings and rear seal for excessive
wear and replace if necessary.

2.

Remove the drip tray by gently lifting up to
disengage from the support and pulling out.
Clean behind the drip tray and front of the
freezer with a soap solution.

Содержание Futura F131

Страница 1: ...Futura F144 and F131 w Blender OWNER S MANUAL Manual No 513603 1 March 2005...

Страница 2: ......

Страница 3: ...are certified in the Stoelting Technicare program Model No _______________________ Serial No _______________________ Purchase Date ____________________ Start Up Date ____________________ CALL Distrib...

Страница 4: ......

Страница 5: ...new parts for freezers built prior to date of change DO NOT ATTEMPT to operate the freezer until instructions and safety precautions in this manual are read completely and are thoroughly understood If...

Страница 6: ......

Страница 7: ...light specific safety information the following safety definitions are provided to assist the reader The purpose of safety symbols is to attract your attention to possible dangers The safety symbols a...

Страница 8: ......

Страница 9: ...Operating Controls and Indicators 7 3 3 Sanitizing 9 3 4 Freeze Down and Operation 10 3 5 Mix Information 11 3 6 Removing Mix from Freezer 11 3 7 Cleaning the Freezer 12 3 8 Disassembly of Freezer Pa...

Страница 10: ...tion Draining 10 15 SanitizingAgitator Shaft 10 16 Dispensing Product 11 17 Removing Mix Inlet Regulator 11 18 Draining Mix 12 19 CleaningAgitator Shaft 12 20 Auger Flight Wear and Front Auger Support...

Страница 11: ...ightspigot withtheconvenienceandcost of one unit The freezer is designed to be used with both barrels in operation If you desire to use one barrel only thefreezermustbecleaned sanitizedandfilledwithfr...

Страница 12: ...s 20 Amp maximum fuse or circuit breakers NEMA 6 20P power cord provided Automatic safeguard circuit built into electronic control protects major freezer components under normal operating conditions R...

Страница 13: ...intain a safe working environment The labels have been designed to withstand washing and cleaning All labels must remain legible for the life of the freezer Fig 3 Warning Label Locations Labels should...

Страница 14: ...nt is necessary level the freezer by turning the bottom part of each leg in or out Then separate freezer base gasket and install with the seam to the back and the flat to the bottom C Air cooled freez...

Страница 15: ...t of the freezer to the door end of the stand Secure the freezer to the stand with the nuts and lock washers provided Then separate freezer base gasket and install the seam to the back and the flat to...

Страница 16: ...6...

Страница 17: ...electrical power has been disconnected SECTION 3 INITIAL SET UP AND OPERATION G Do not operate under unsafe operating condi tions Never operate the freezer if unusual or exces sive noise or vibration...

Страница 18: ...green light illuminates before dispens ing E CLEAN SWITCH TheCLEANswitchisa snap switch Whentheswitch is pushed the refrigeration system will be OFF and the auger will rotate for cleaning When the swi...

Страница 19: ...MENT BE CERTIFIED FOR THIS USE When sanitizing the freezer refer to local sanitary regulations for applicable codes and recommended sanitizing products and procedures The frequency of sanitizing must...

Страница 20: ...e top of the air inlet tube on the mix inlet regulator E The freezer barrel will automatically fill until it is about 1 2 full If freezer barrel does not fill check for obstruction in the mix inlet re...

Страница 21: ...al State and local regulatory agencies Figure 16 Dispensing Product 3 5 MIX INFORMATION Mix can vary considerably from one manufacturer to another Differences in the amount of butterfat content and qu...

Страница 22: ...er When the water has drained turn the OFF ON switch to the OFF position Allow the freezer barrel to drain completely CAUTION Hazardous Moving Parts Revolving blender agitator shaft can grab and cause...

Страница 23: ...s Fig 21 Figure 21 Removing Front Door C Remove the rosette caps from the front door Push the spigot body through the bottom of the front door and remove Fig 22 Figure 22 Front Door Disassembly D Remo...

Страница 24: ...remove and let air dry C Using this sanitizing solution and the large barrel brush provided sanitize the rear of the barrel and drive area by dipping the brush in the sanitizing solution and brushing...

Страница 25: ...he surface of the cam on the spigot handle prior to assembly of handle to the spigot body H Install the spigot bodies with O rings into the front door from the bottom Fig 27 Push straight up until the...

Страница 26: ...g efforts within a layer of soil material milkstone Thorough cleaningproceduresthatinvolvemilkstone removal are critical for operators of frozen dessertmachines SANITIZING Kills bacteria Can be effect...

Страница 27: ...the ability to remove milkstone Milkstone will become a problem if not remedied with additional products and procedures THE USE OF CHLORINE TEST STRIPS Test strips are used to determine concentration...

Страница 28: ...ire periodic cleaning To clean refer to the following procedures 1 Remove the Phillips head screw from the bottom of the right side panel and then slide the panels down and out 2 To remove the condens...

Страница 29: ......

Страница 30: ...20...

Страница 31: ...t s u j d a e R 3 e c i v r e s r o f r o t u b i r t s i d l l a C e c a l p e R 4 r o f r o t u b i r t s i d l l a C m e t s y s k c e h C 5 e c i v r e s o o t s i t c u d o r P t f o s n e h w d...

Страница 32: ...t r i a r o t a l u g e r t e l n i x i M 4 d e k c o l b n w o d k a e r b t c u d o r P 5 e z e e r f d n a e z i t i n a s n a e l c x i m e v o m e R 1 x i m h s e r f h t i w n w o d r o t a l u...

Страница 33: ...te timer will not time out A flashing clean light is not an error NOTE Flashing CLEAN light is not an error It indicates the freezer is in the CLEAN mode To exit turn the OFF ON switch to the OFF posi...