Setting Up

Handling

Unpacking

Positioning

Installation

•  Use suitable means to move the unit: e�g�  

- For smaller items use two people 
- For large items a fork lift, pallet trolley or similar (the forks should reach completely beneath the pallet)

•  Check the unit for damage before and after unpacking�  If unit is damaged, contact the distributor and manufacturer
•  Should any item have physical damage, report the details to the freight company and to the agent responsible for the dispatch within 

seven (7) days of receipt�  No claims will be accepted or processed after this period

•  The unit is supplied fully assembled
•  Remove all protective plastic film, tapes, ties and packers before installing and operating
•  Clean off any remaining residue from the interior/exterior of the unit using a clean cloth dampened with warm soapy water

•  Choose an area that is well ventilated and provides access for future maintenance
•  Place the unit on a level stable work surface capable of supporting its weight
•  Do not position the unit in: wet areas, near heat and/or steam sources, near flammable substances
•  Allow 50mm air gap at the rear of the unit

WARNING

Improper installation, adjustments, alterations, service or 

maintenance can cause property damage, injury or death.

This unit must be installed in accordance with AS/NZS 60335.1

Some procedures in this manual require the power to the equipment to be turned off  and 

isolated.  Turn the power OFF at the power point and unplug the power supply lead by the plug 

body.  If the power point is not readily accessible turn the equipment off  at the isolation switch 

or the circuit breaker in the switchboard.  Attach a yellow “CAUTION-DO NOT OPERATE” tag. 

This must be performed where relevant unless the procedures specify otherwise.

FAILURE TO DO SO MAY RESULT IN ELECTRIC SHOCK.

WARNING

Single Phase Units:

•  Supplied and fi tted with an appropriately rated plug and lead, indicated as:

- 10A plug & lead fi tted

Notes:

•  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a 

hazard�  Please contact Stoddart for parts and we will advise how to do this in order to avoid any electrical hazard

•  The power cable should be dry and/or isolated from moisture or water

Electrical Connection

Содержание Culinaire CH.WD

Страница 1: ...he use care and maintenance of your quality Culinaire product Models CH WD 0111 CH WD 0211 WARMING DRAWERS SPECIFICATION INSTALLATION AND OPERATION MANUAL READ ALL INSTRUCTIONS BEFORE USE Revision 02...

Страница 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 3: ...ing Electrical Connection 6 Specification Technical Specifications 7 Code Explanation CH WD 0111 CH WD 0211 Operation Initial Start up Operation 9 Warming Drawer Initial Start up Warming Drawer Operat...

Страница 4: ...his product is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or in...

Страница 5: ...bjects to activate controls If any fault is detected refer to troubleshooting The manufacturer declines any liability for damages to persons and or things due to an improper wrong and or unreasonable...

Страница 6: ...is subject to change without notice www stoddart com au www stoddart co nz Code Explanation CH Culinaire Heated WD Warming Drawer 0111 1 x 1 1 GN pans 0211 2 x 1 1 GN pans CT Castor Trolley Warming Dr...

Страница 7: ...apable of supporting its weight Do not position the unit in wet areas near heat and or steam sources near flammable substances Allow 50mm air gap at the rear of the unit WARNING Improper installation...

Страница 8: ...lanation CH WD 0111 SPECIFICATIONS Model CH WD 0111 Width 618mm Depth 625mm Height 343mm Capacity 1 x 1 1 Gastronorm Pans Voltage 220 240V 50Hz Power kW 0 55W 10 A plug lead fitted Connection 1 Phase...

Страница 9: ...ddart com au www stoddart co nz Specification CH WD 0211 SPECIFICATIONS Model CH WD 0211 Width 618mm Depth 625mm Height 550mm Capacity 2 x 1 1 Gastronorm Pans Voltage 220 240V 50Hz Power kW 1 12kW 10...

Страница 10: ...other switch can operate if the POWER button is OFF Ensure that the power cord is stored out of the way and can not be damaged The heater pads can be switch ON or OFF and the temperature can be adjus...

Страница 11: ...ked Food Storage Food Safety All Gastronorm pans are sold separately Ensure only 1 type of product is placed in each pan to prevent cross contamination If more pans are needed contact your distributor...

Страница 12: ...rasive pads or cleaners for cleaning All metal surfaces should be checked while cleaning for damage scuffs or scrapes as these can lead to rust and further damage to the product Mild rust and or corro...

Страница 13: ...until all soil has been removed 6 Using a clean sanitised cloth thoroughly wipe the stainless steel and metal parts dry Do NOT let water pool on the unit Check crevices and folds Cleaning Procedure Ex...

Страница 14: ...mostat failure T Test and replace the element or thermostat if necessary WARNING Technician tasks are only to be completed by qualified service people Check faults before calling service technician If...