8 | Commissioning
STOBER
44
02/2020 | ID 442516.07
8.3.8
Checking the functionality of the axes
Check the functionality of the axes before operation in production.
Information
Ensure that a suitable safety application that ensures safe shut-off of the axis (emergency off, safety switch, etc.) exists
before the start of testing.
Information
In order to be able to check the function of the axes, parameter
A541 Modes of operation
of the respective axis must be
set to the value
8
.
1.
In the solution explorer, navigate to
Motion
>
NC-Task 1 SAF
>
Axes
>
Axis 1
.
2.
In the main window, switch to the
Online
tab.
ð
The
Set Enabling
dialog box opens.
3.
Activate the options
Controller
,
Feed Fw
,
Feed Bw
.
Override
: Enter a value for the override (e.g. 100).
4.
Confirm with
OK
.
ð
The axis is monitored using the active control panel.
5.
F1 – F4
:
Move the axis step-by-step and test the movement direction, velocity, etc. using the corresponding buttons.
6.
To deactivate the enable signal, click on
Set Enabling
and deactivate the options
Controller
,
Feed Fw
,
Feed Bw
.
7.
Repeat steps 1 – 6 for each additional axis of your system.