www.stobag.com
20
Operating instructions
AIROMATIC PS4500 | TARGA PS6000 | PERGOLINO P3500
Drive system
Fig. 11: Drive system
The electric motor (fig. 11/1) is an AC induction
motor. Power is transmitted on both sides via
gears to a toothed belts with Kevlar reinforce-
ment, which drives the drop-out profile. The drive
is controlled using a remote control.
Fabric stop block (PERGOLINO model)
Fig. 12: Fabric stop block
The fabric stop block is located to the left and
right on the front yoke of the frame. The fabric
panel travels to the final position. The stop block
is inserted with the hook rod and locks the ex-
tended fabric panel in place.
The fabric panel is pulled back, held by the lock
function and thus tightened. This prevents the
fabric panel from flapping and puddle formation
in case of rain.