Installation
Check that the mounting surface is suitable for the
installation of this fitting.
Fitting weight: 2kg
Step 1 Make mains connections to SELV LED driver
and extra low voltage connections to the
fitting.
Step 2 Secure fitting in place using two suitable
screws.
After opening the sealed portion of the luminaire for
any reason, MSL recommends running the fitting for
15 minutes with the lid open to expel moisture before
closing it up. This will prevent condensation on the
lens and protect the fitting from corrosion.
WARNING: Do not look at exposed LED lamps in
operation. Eye injury can result.
Cleaning:
Fully isolate the fitting and allow to cool.
Clean the fitting with a slightly damp lint free cloth
from a mild solution of soap and water. The fitting
must be completely dry before reconnecting power.
Incompatible or abrasive chemicals can damage the
fitting, contact MSL for advice if required.
Electrical Supply
Installation must be carried out by a qualified electrician in
accordance with BS 7671:2008 Wiring Regulations.
230/240V AC 50/60Hz mains supply to a suitable SELV
LED Driver.
Site conditions: LED equipment is more susceptible to
static damage and overvoltage than previous technology.
Before handling or connecting to the mains supply ensure
that all MSL products are protected from static discharge
and that the mains supply is to regulation. (230V +10
-6%)
This fitting is supplied with a Xicato LED module. Refer to
the fitting label for the module version and wattage. More
information on the module can be found at
www.xicato.com/support
Mains cables must be double insulated, strain relieved
and separated from E.L.V output cables.
This unit requires a constant current driver. 1050mA Max.
Observe polarity:
Positive (+) is marked as 1.
Incorrect supply or reverse polarity can cause irreparable
damage.
All connections must be made before switching on mains.
If the supply is energised prior to making the connections
to the fitting then the resulting surge will damage the LED.
All lighting equipment is delicate and easily damaged
through misuse or inappropriate installation (mechanical
or electrical). Repairs and replacements may cause
delays and will be chargeable. Contact MSL for support if
required. For full warranty terms & conditions please visit
our website.
Dimming control circuit source must be of SELV insulation
class.
The IP rating stated is applicable only when the fitting has
been installed as per these instructions.
Ensure supply driver and connectors are housed indoors
OR in a suitable IP rated enclosure.
2
410 381 1497 inter-lux.com [email protected]
Inter-lux reserves the right to make technical changes without notice.
STOANE