1.6
Performance
The
evaluation board performance characteristics include:
•
Stand-by losses < 300 mW (@ 240 V)
•
IEC 61000-4-4 (STEVAL-GLA001V1 evaluation board with
–
2 kV criteria A
–
4 kV criteria B
1.7
AC switch load capability
The
evaluation board is designed to operate with the following load conditions:
Table 1.
Load capability versus ambient temperature and AC switch
Ambient temperature
0 °C
25 °C
60 °C
Load 1
7.2 A = 1650 W
6.2 A = 1430 W
4.6 A = 1050 W
Load 2
1.5 A = 350 W
1.3 A = 300 W
0.9 A = 205 W
Load 3
0.9 A = 200 W
0.75 A = 170 W
0.5 A = 115 W
Total loads power
2200 W
1900 W
1370 W
All of the above values are RMS, for V
MAINS
= 230 V
RMS
and with 5% tolerance on the maximum allowed AC
switch junction temperature.
Load numbers are given with reference to the following figure.
Figure 3.
Loads connection versus AC switches
UM2304
Performance
UM2304
-
Rev 3
page 4/46