10
STEVAL-GLA001V1 power losses
evaluation board generates limited standby power losses due to the components directly
connected to the mains voltage and to the secondary side power supply, including:
•
ZVS circuit
•
LED circuit (high voltage presence)
•
MODE switch circuit
•
Power supply regulation circuit (secondary)
•
LED circuit (VDD voltage)
Standby power losses measurement has been performed using a power meter under the following conditions:
•
Vmains = 240 Vrms / 60 Hz
•
Tamb = 22 °C
•
VDD = 5 V (worst case)
•
MODE switch in On/off position (worst case)
Table 9.
Typical STEVAL-GLA001V1 standby losses
Vmains
I(input)
P(input)
240 V / 60 Hz
10 mA
288 mW
UM2304
STEVAL-GLA001V1 power losses
UM2304
-
Rev 3
page 38/46