Gas connection
• Accessibility
: Make sure that it is possible to run gas lines to the gas
connection point of the appliance. The gas connection point must be
accessible without having to remove the cooktop. If a flexible hose is
used, the connection point must also be accessible without having to
remove the cooktop.
• Natural gas connection:
Using the supplied gas regulator (Fig. 8), remove
the dust seals on the inlet and outlet ports and position the “OUT” port
of the regulator towards the gas inlet pipe of the cooktop, as illustrated in
Fig. 9. Using a suitable thread sealant, screw the regulator on and ensure
that it is orientated with easy access to the test point (Fig. 10). Connect the
appropriate Natural Gas supply to the “IN” port of the gas regulator.
Fig. 10
Fig. 9
Gas
regulator
test point
Outlet port to
gas cooktop
Gas
supply
inlet
port
Fig. 8
Installation (Cont.)
Gas conversion
This 5 Burner Gas Cooktop is fitted out for use with Natural Gas (NG). If it
is to be used with liquefied petroleum gas (ULPG), the burners have to be
converted. Before starting the conversion, make sure all gas is switched off
(and preferably disconnected from the appliance) and the electrical power has
been disconnected.