14
MODEL: SGC62 | PRODUCT CODE: 53593 | 06/2016
Installation Cont.
Remove (A) all the trivets, burner cap and burner base from the cooktop.
Remove the injectors (B) and replace with the LPG injectors supplied with your cooktop.
Refer to the rating plate (Table 2.) for the correct injector sizes for each burner.
Reassemble all the burners carefully (refer to Fig. 19 on page 20); in particular you should make sure that the
burner base is correctly placed on the burner.
Follow gas connection instructions but do not install the NG regulator (Fig. 9 on page 13) but install the brass
test point fi tting (Fig. 10 on page 13).
Table 2