STILLE 6202 Скачать руководство пользователя страница 1

 

 

   

 

 

Service Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 

 

 

 

 

 

Gynaecology/Urology Table 6300 series 

 

Urodymanics Table 6202 

 

 

 
 
 
 
 
 

  

Содержание 6202

Страница 1: ...Service Manual Gynaecology Urology Table 6300 series Urodymanics Table 6202 ...

Страница 2: ...information 18 Removal and replacement procedures 18 Removal replacement list 18 What to do 18 Remove Replace power cord 19 Remove Replace Foot control Hand control 20 Remove Replace Control box 21 Remove Replace Lift motor 22 Remove Replace Seat motor 23 Remove Replace Back motor 24 Remove Replace Gas piston 25 Remove Replace Gas piston for foot rest 26 Remove Replace Back cushion 28 General Asse...

Страница 3: ...ned to improve readability and increase understanding of its content Adhere to the following recommendations and the ones in the User Manual for safe operation of the device and service See below and in the user manual NOTE Sets apart special information or important instruction clarification WARNING symbol identifies situations or actions that may affect patient or user safety Disregarding a warn...

Страница 4: ...f Unplug the power connector from its power source before cleaning or servicing Failure to do so could re sult in equipment damage Ensure that the power cord does not become pinched between mechanisms during normal operation of the table Failure to do so can result in equipment damage Do not connect the power connector or any control unit connector to anything other than the appropriate input on t...

Страница 5: ...P66 Degree of protection EN 60529 ingress of water and foreign objects 170 kg Max safe workload icon max safe workload 170Kg 6 Min H Duty cycle icon duty cycle 6 min H or 10 Explanations of the symbols found in the user manual Moves said part up Moves said part down Secure Release Push Insertion direction part Adjustable in shown directions Adjustable in shown directions Adjustable in shown direct...

Страница 6: ...model dependant to set the table and patient in the desired position see description of controls For accessories installed or delivered separately see accessories list and installation 1 2 3 4 5 6 7 8 9 10 11 12 13 Description 1 Back cushion 2 Seat cushion 3 Rissler leg rest 4 Leg rest adjustment screw Use hand screw to secure and to release 5 Drainage receptacle container and holder 6 Foot contro...

Страница 7: ...ltage to the motors to 24V DC The table uses foot or hand controls optional to set the table and patient in the desired position see descrip tion of controls For accessories installed or delivered separately see accessories list and installation 7 8 1 2 3 9 11 12 13 14 10 5 6 4 Description 1 Back cushion 2 Seat cushion 3 Arm rest 4 Rissler leg rest 5 Foot rest 6 Foot control 7 Adjustable paper rol...

Страница 8: ...y 30 90 30 C not condensing Atmospheric pressure 700hPa 1060hPa Disposal backup battery battery drive system optional No part requires special disposal except the battery options backup battery and battery drive system The backup battery battery drive system shall be disposed due to its material Pb contact your maintenance technician for assistance in disposing the battery Measures and weights Tab...

Страница 9: ...egard ing allowable leakage current Degree of protection against electric shock Type B Body Equipment providing particular degree of protection against electric shock particularly regarding allowable leakage current Degree of protection against harmful ingress of water IP66 Degree of safety in presence of inflammable anesthetics The device is not intended for use with flammable anesthetic gases Mo...

Страница 10: ...truction and document the maintenance in the record field Check each item according to the instruction and make necessary adjustments If in doubt replace the relevant parts Also check to see that none of the table components have been removed or modified If so replace with original parts Acronyms definitions OK Inspected checked tested ok NOK Inspected checked tested Not ok C Cleaned A Adjusted RA...

Страница 11: ... positioning Use the back cushion release handle or quick release op tional to check that its possible to lower the back cushion to more then 12 8 Wheels Inspect wheels for wear or damage Apply brake and ensure the ta ble will not move Replace if needed Drainage Inspect drainage container for dents or cracks Inspect holder for damage Replace if needed Cushions Inspect the cushions for wear cuts st...

Страница 12: ...e table and follow the instructions in that section Symptom list Symptom Page Controls do not operate the table 13 14 The Lift motor will not operate or have other problem 15 The Seat motor will not operate or have other problem 15 The Back motor will not operate or have other problem 15 The Gas pistons will not operate or has other problem 17 Wheels have reduced braking ability or other problem 1...

Страница 13: ...the table with that hand foot control instead of test measuring Verify each switch on hand foot control Switch open shall be 10KΩ or greater Switch closed Shall be 10Ω or less 12 Activate up table measure pin 0 vs pin 1 13 Activate down table measure pin 0 vs pin 2 14 Activate up seat measure pin 0 vs pin 4 15 Activate down seat measure pin 0 vs pin 3 16 Activate up back measure pin 0 vs pin 8 17 ...

Страница 14: ...ot op erate 10 Switch motor cables to verify any motor failure or control box output failure Action removal and replacement Description location picture comments 1 Use hand foot control test all functions Note pin 0 is the center pin Note pin 1 is shield 2 If no connection activated replace control 3 If no connection activated replace control 4 If no connection activated replace control 5 If no co...

Страница 15: ... to the lift motor and install it into the output for the seat back mo tor Check function Note that symbols on the foot hand control now doesn t match the func tions Does the motor run properly on another control box output 7 Check foot hand control Check foot hand control unit and cord for visible damage cuts dents etc 8 Test measure hand foot control See section Symptoms Issues controls do not o...

Страница 16: ... the foot plate is not damaged or worn out 4 The hydraulic parts Check that the gas piston is not damaged or bent 5 Check that the release handle is not damaged or bent 6 Check that it is possible to adjust the angel of the foot rest by pushing the release handle Also check that it locks in that angle when weight is put on the foot rest Action removal and replacement Description location picture c...

Страница 17: ...tion picture comments 1 Replace if missing 2 Replace if needed 3 Replace if needed 4 Adjust gas pistons See replacement proce dure Symptom Wheels have reduced braking ability or other problem Check Inspect verify 1 Check if the wheel has been Damaged Excessively worn etc Inspect condition of the wheel 2 Check that the wheel can spin freely and than no debris has been caught inside the wheel Inspec...

Страница 18: ...rop erty damage could occur CAUTION Use only Stille Sonesta spare parts Removal and replacement procedures Below is a list of removal replacement procedures find the one s that is referenced from the symptoms issue finding and follow the instructions in that section Removal replacement list Removal Replacement Page Power cord 19 Foot control Hand control 20 Control box 21 Lift motor 22 Seat motor ...

Страница 19: ... Gently press inwards on the red locking tab on the control box with the screwdriver while unplugging the power cord from the control box Note you may need to press the red tab on the opposite side as well To do replace 1 Install the new power cord use only IP66 power cord into the control box 2 Plug the power connector into the power supply wall outlet 3 Perform test according to preventive maint...

Страница 20: ...om the power supply wall outlet 3 Gently release the locking tab on the connector retaining clip on the Control box remove connector retaining clip 4 Unplug the connector for the foot control hand control from the control box It can be quite tight be sure not pull on the cable To do replace 1 Plug in the connector from the replacement foot hand control into the control box 2 Install the connector ...

Страница 21: ...nection to the control box during replacement 5 Unplug all connectors from the control box 6 Remove the two Allen screws holding the control box and bracket Remove the control box from the table 7 Disconnect the potential equalization ground cable and power cable from the control box 1 To do replace 2 Mount the potential equalization ground cable to the connector on the control box Small flat tip ...

Страница 22: ...Unplug connector to lift motor from control box 9 Remove plastic plugs which the lift motor cable runs through on the lift beam 10 Route the lift motor cable out of the lift beam 11 Remove the Allen screw and nut holding the lower motor brackets carefully pull the motor axle out and remove brackets 12 Remove the Allen screw and nut holding the upper motor bracket carefully pull the motor axle out ...

Страница 23: ...ame steady as it will be loose as soon as the motor axle is removed 12 When motor bracket is removed carefully lower the seat frame making sure not to pinch the motor cable or damaging the paint 13 Remove the Allen screw and nut holding the upper motor bracket carefully pull the motor axle out while holding motor remove bracket and seat motor To do replace 1 Install the replacement seat motor moun...

Страница 24: ...ive cable ties holding the back motor cable to the back frame and back motor housing 12 Remove the Allen screw and nut holding the lower motor brackets carefully pull the motor axle out and remove brackets 13 Remove the Allen screw and nut holding the upper motor bracket carefully pull the motor axle out while holding the motor remove bracket and back motor To do replace 1 Install the replacement ...

Страница 25: ...the gas piston Loosen fork and move it to replacement gas pis ton Thread it down the same distance as on old gas piston 1 To do replace 2 Mount the replacement gas piston into the lower mounting point adjust screw and tighten locking nut to a 0 2 0 4mm play See views 3 Install the gas piston fork to the back frame with bolt and nut ad just the length of the gas piston by threading the fork in or o...

Страница 26: ...e assembly is threaded down onto the top of the old gas piston Then loosen the assembly and move it to the replacement gas piston Thread it down the same distance as on old gas piston together with locking nut To do replace 1 Mount the replacement gas piston into the lower mounting point push axle in mount plastic spacers and press Starlock retainer back on again 2 Also mount the replacement gas p...

Страница 27: ...27 56 3 Ref A 4 Ref B 2 Ref C 3 Ref D ...

Страница 28: ... Raise back section to it s highest position 3 Unplug the power cord from the power supply wall outlet 4 Hold the back cushion in place and remove the six screws that secure it 5 Remove back cushion To do replace 1 Mount the back cushion to the back frame by installing the six screws that secure it 2 Make sure to position the screws in the pre marked holes so the cushion is positioned correctly on...

Страница 29: ...29 56 General Assembly for Table 6300 series The following page shows the drawings for assemblies and part lists ...

Страница 30: ...30 56 Assembly Bottom frame Table 6300 series ...

Страница 31: ...31 56 Part list ...

Страница 32: ...32 56 Complete Assembly 3 motors Table 6300 series ...

Страница 33: ...33 56 Part list ...

Страница 34: ...34 56 Part Assembly 3 motors Table 6300 series ...

Страница 35: ...35 56 Part List ...

Страница 36: ...36 56 Complete Assembly 2 motors Table 6300 series ...

Страница 37: ...37 56 Part List ...

Страница 38: ...38 56 Part Assembly 2 motors Table 6300 series ...

Страница 39: ...39 56 Part List ...

Страница 40: ...40 56 Complete Assembly 2 motors fixed seat Table 6300 series ...

Страница 41: ...41 56 Part List ...

Страница 42: ...42 56 Part Assembly 2 motors fixed seat Table 6300 series ...

Страница 43: ...43 56 Part List ...

Страница 44: ...44 56 Electrical System Diagram 230 120 V Table 6300 series ...

Страница 45: ...45 56 General Assembly for Table 6202 The following page shows the drawings for assemblies and part lists ...

Страница 46: ...46 56 Assembly Complete 6202 ...

Страница 47: ...47 56 Part list 6202 ...

Страница 48: ...48 56 Part Assembly 1 of 2 6202 ...

Страница 49: ...49 56 Part List 1 of 2 6202 ...

Страница 50: ...50 56 Part assembly 2 of 2 6202 ...

Страница 51: ...51 56 Part List 6202 ...

Страница 52: ...Assembly Bottom frame 6202 ...

Страница 53: ...53 56 Part List 6202 ...

Страница 54: ...Electrical System diagram 230 120 V Table 6202 ...

Страница 55: ...55 56 Notes ...

Страница 56: ...e http www stille se USA STILLE Surgical Inc 943 Parkview Boulevard Lombard IL 60148 United States Tel 1 800 665 1614 Manufactured by STILLE AB Sundbybergsvägen 1a SE 171 73 Solna Sweden Tel 46 8 588 58 000 Fax 46 8 588 58 005 E mail info stille se http www stille se 950 S6000 09EN 01 Service Manual Printed in Sweden April 2009 Engelska ...