SR 440
English
48
Hectares (ha) have to be converted into
m
2
(ha x 10,000 = m
2
).
To adjust the required discharge rate
see "Metering Unit".
Valve lever
Solution feed is started and stopped with
the valve lever (1).
N
Position A (valve lever vertical, up) –
open
N
Position B (valve lever horizontal,
down) – closed
Metering knobs
The scope of supply includes metering
knobs which allow a wide range of
different discharge rates.
–
Standard metering knob (A) with
positions 1 to 6
–
ULV metering knob
1)
(B) with
positions 0.5 to 0.8
Changing the metering knob
N
Pull the existing metering knob up
and out of its seat.
N
Push the new metering knob into its
seat as far as stop.
144 l x 10 (m/min) x 4 m
= 1.6 l/min
3,600 m
2
Metering Unit
1
0002BA061 KN
A
B
1
1)
Standard equipment in some
markets or available as special
accessory
0002BA103KN
A
B
0002BA065 KN