iNSTallaTiON
Installation
16
| WPE-I H(K)W 230 Premium
www.stiebel-eltron.com
9.11 Operation with buffer cylinder
f
Install the supplied TAF PT immersion/contact sensor.
f
Connect the sensor to the heat pump manager.
f
Adjust the parameter.
Parameter
Setting
BUFFER OPERATION (SETTINGS / HEATING / STANDARD
SETTINGS)
ON
WPE-I HKW 230 Premium
For cooling in combination with a buffer cylinder, an additional
TAF PT immersion / contact sensor is required.
f
Install the sensor in the buffer cylinder flow.
f
Connect the sensor to the heat pump manager.
9.12 Fitting the push-fit connectors
D
00000
58
81
7
1
2
3
1 Plastic push-fit connectors, heat source side
2 Plastic push-fit connectors, heating side
3 Copper push-fit connectors, DHW side
9.12.1 Installing plastic push-fit connectors (heating side and
heat source side)
Note
The plastic push-fit connectors are not suitable for instal-
lation in the DHW line.
f
Only install the push-fit connectors in the heating or
brine circuits.
!
Material losses
f
Tighten the screw cap of the push-fit connector by
hand. Never use a tool.
Material losses
To ensure the push-fit connector is held securely, pipes
with a surface hardness > 225 HV (e.g. stainless steel)
must have a groove.
f
Using a pipe cutter, cut a groove (depth ap-
prox. 0.1 mm) at a defined distance from the end of
the pipe.
- Pipe diameter 22 mm: 17±0.5 mm
- Pipe diameter 28 mm: 21±0.5 mm
!
Material losses
Support sleeves are required when using plastic pipes.
How the push-fit connectors work
The push-fit connectors are equipped with a retainer with stain-
less steel serrations and an O-ring for sealing. In addition, the
push-fit connectors are equipped with the "twist and lock" func-
tion. Simply turning the screw cap by hand will secure the pipe
in the connector and push the O-ring against the pipe to seal it.
Making the push-fit connection
The connector must be in its relaxed position before the pipe is
inserted. In this position, there is a small gap between the screw
cap and main body.
D
00000
88
51
9
1
2
3
4
1 Retainer
2 Screw cap
3 Gap between screw cap and main body
4 Main body
D
00000
88
52
0
Pipe Ø
22 mm
28 mm
Depth of insertion A
max. 38 mm
max. 44 mm
!
Material losses
Pipe ends must be deburred.
f
Always use a pipe cutter to trim pipes.
f
Push the pipe past the O-ring into the push-fit connector
until it reaches the prescribed insertion depth.
f
Finger-tighten the screw cap as far as it will go against main
body. This secures the push-fit connection.
Содержание WPE-I 04 HKW 230 Premium
Страница 29: ...Installation Specification www stiebel eltron com WPE I H K W 230 Premium 29 ...
Страница 45: ...www stiebel eltron com WPE I H K W 230 Premium 45 NOTES ...
Страница 46: ...46 WPE I H K W 230 Premium www stiebel eltron com NOTES ...
Страница 47: ...www stiebel eltron com WPE I H K W 230 Premium 47 NOTES ...