![STIEBEL ELTRON SBP 100 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/stiebel-eltron/sbp-100/sbp-100_operation-and-installation_1377124009.webp)
EN
GL
ISH
www.stiebel-eltron.com
SBP 100|
29
INSTALLATION
Installation
WPKI-P E
The compact heat pump installation comprises all necessary com-
ponents for connecting the heat pump to the SBP 100 cylinder.
0
bar
2
4
1
3
20
0
40
60
80
100
120
°C
D
00000
35
88
0
1
3
4
5
7
8
9
10
11
6
2
Heat pump flow
1 Connection bend G 1 ¼
2 Wall mounting bracket
3 Ball shut-off valve with non-return valve
4 Ball shut-off valve
5 Thermometer
6 Safety valve with pressure gauge
7 Connector G 1 ¼
Heat pump return
8 Connector G 1 ¼ with connection for drain valve and expan-
sion vessel
9 Ball shut-off valve
10 Connector G 1 ¼ with sensor well for return temperature
sensor
11 EPS insulation parts
WPKI-W E
The compact heat pump installation comprises all necessary com-
ponents for connecting to a DHW cylinder.
20
0
40
60
80
100
120
°C
D
00000
35
88
1
2
1
6
5
4
7
3
DHW return
1 EPS insulation parts
2 Connector G 1 ¼ for installation in the heat pump return
DHW flow
3 Connector G 1 ¼ for installation in the heat pump flow
4 Connection bend
5 Ball shut-off valve
6 Thermometer
7 Connector G 1 with ball shut-off valve and non-return valve