2.1 Intended use
This appliance is intended to be used for heating and cooling
interiors (area cooling 18 °C / 23 °C) and for DHW heating.
The appliance is intended for domestic use. It can be used safely
by untrained persons. The appliance can also be used in a non-do-
mestic environment, e.g. in a small business, as long as it is used
in the same way.
Any other use beyond that described shall be deemed inappro-
priate. Observation of these instructions and of the instructions
for any accessories used is also part of the correct use of this
appliance.
2.2 General safety instructions
WARNING Burns
There is a risk of scalding at outlet temperatures in ex-
cess of 43 °C.
!
WARNING Injury
The appliance may be used by children over 8 years of
age and persons with reduced physical, sensory or men-
tal capabilities or a lack of experience and expertise,
provided that they are supervised or they have been
instructed on how to use the appliance safely and have
understood the potential risks. Children must never play
with the appliance. Children must never clean the ap-
pliance or perform user maintenance unless they are
supervised.
!
WARNING Injury
For safety reasons, only operate the appliance with the
front casing closed.
Note
The DHW cylinder is under mains pressure. During the
heat-up process, expansion water will drip from the safe-
ty valve.
f
f
If water continues to drip when heating is complet-
ed, please inform your qualified contractor.
!
Material losses
The system's active frost protection is not guaranteed if
the power supply is interrupted.
f
f
Never interrupt the power supply even outside the
heating season.
2.3 Test symbols
See type plate on the appliance.
3. Appliance compatibility
The appliance can be operated in conjunction with the following
air | water heat pumps:
- WPL 09 ICS classic
- WPL 09 IKCS classic
- WPL 17 ICS classic
- WPL 17 IKCS classic
4. Appliance description
The buffer cylinder and DHW cylinder with indirect coil are ar-
ranged one above the other and can be separated for easier han-
dling.
The appliance has a plastic jacket with foam insulation and is
equipped with a removable front casing. The appliance is connect-
ed hydraulically and electrically to the heat pump. All hydraulic
connections are made at the top and rear.
In addition to the DHW cylinder and the buffer cylinder, a highly
efficient circulation pump is also integrated for a heating circuit
without mixer.
DHW cylinder
The steel cylinder is coated on the inside with special direct enam-
el and is equipped with a signal anode. The anode with consump-
tion indicator protects the cylinder interior from corrosion.
The heating water heated by the heat pump is pumped through an
indirect coil inside the DHW cylinder. The heat channelled through
the indirect coil is thus transferred to the domestic hot water.
Buffer cylinder
The steel cylinder provides hydraulic separation between the flow
rates of heat pump and heating circuit. The heating water heated
by the heat pump is transferred into the buffer cylinder. When a
demand is issued, the integral heating circuit pump delivers the
heating water to the heating circuit.
328453_HSBC_200_L_de_en_fr_nl_it_cs.indb 24
17.10.2017 08:25:34