Specification

FCR 28/270 Si, part number 075141 

FCR 28/360 Si, part number 075124 

FSR 28/90, part number 004817 

FSR 28/180, part number 004785

9, 18, 27, 36 kW, 3/PE ~ 400 V

6

5

4

L3

L2

L1

4

5

3

1

2

85

�02

�7

9�

00

02

1  Heating element 

9 kW connected load: 9 x 1 kW 

18 kW connected load: 9 x 2 kW 

27 kW connected load: 9 x 3 kW 

36 kW connected load: 9 x 4 kW

2  Thermostat

3  High limit safety cut-out

4  Contactor, installed by the heating contractor

5  Power-OFF contact, installed by the heating contractor

!

 

Material losses

When connecting the contactors, please observe chapter 

"Installation / Power connection".

Содержание FCR 28/120 Si

Страница 1: ...OPERATION AND INSTALLATION UTILISATION ET INSTALLATION BEDIENING EN INSTALLATIE Heizflansch Flanged immersion heater Corps de chauffe Verwarmingsflens FCR 28 120 Si FCR 28 180 Si FCR 28 270 Si FCR 28...

Страница 2: ...the heating elements and protective pipe 17 14 Specification 18 14 1 Dimensions immersion depths and connections 18 14 2 Wiring diagrams and connections 18 14 3 Data table 20 GUARANTEE ENVIRONMENT AN...

Страница 3: ...emperatures in ex cess of 43 C WARNING Injury The appliance may be used by children aged 8 and up and persons with reduced physical sensory or mental capabilities or a lack of experience provided that...

Страница 4: ...ommercially available des caling agents f f Regularly activate the safety valve to prevent it from becom ing blocked e g by limescale deposits 6 Troubleshooting Fault Cause Remedy The water does not h...

Страница 5: ...ge pipe of the safety valve with a constant downward slope and in a room free from the risk of frost f f The safety valve discharge aperture must remain open to the atmosphere 8 Appliance description...

Страница 6: ...immersion heater The contactors must be switched inde pendently of one another by the thermostats and the high limit safety cut out respectively see chapter Specifica tion Wiring diagrams and connect...

Страница 7: ...high limit safety cut out has responded because the controller is faulty Replace the thermostat and press the high limit safety cut out reset button The high limit safety cut out has responded because...

Страница 8: ...cables PG 13 5 2 Entry electrical cables PG 21 Mating flange 245 219 205 83 14 280 26_02_79_0013 14 2 Wiring diagrams and connections FCR 28 120 Si part number 075140 FCR 28 180 Si part number 075131...

Страница 9: ...6 5 4 L3 L2 L1 4 5 3 1 2 85_02_79_0002 1 Heating element 9 kW connected load 9 x 1 kW 18 kW connected load 9 x 2 kW 27 kW connected load 9 x 3 kW 36 kW connected load 9 x 4 kW 2 Thermostat 3 High limi...

Страница 10: ...00 300 300 Versions IP rating IP24 IP24 IP24 IP24 IP24 IP24 Dimensions External flange diameter mm 280 280 280 280 280 280 Immersion depth mm 325 325 325 450 450 450 Torque Nm 80 80 80 80 80 80 Weight...

Страница 11: ...Y Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26...

Отзывы: