STIEBEL ELTRON FCR 28/120 Si Скачать руководство пользователя страница 3

OPERATION 

 

Safety

www.stiebel-eltron.com 

FCR 28 Si | 

13

EN

GL

ISH

1.2  Other symbols in this documentation

 

Note

General information is identified by the symbol shown 

on the left.

f

f

Read these texts carefully.

Symbol

Meaning

 

 

Material losses

(Appliance and consequential losses, environmental pol-

lution)

 

 

Appliance disposal 

 

f

f

This symbol indicates that you have to do something. The ac-

tion you need to take is described step by step.

1.3  Units of measurement

 

Note

All measurements are given in mm unless stated oth-

erwise.

2.  Safety

2.1  Intended use

The appliance is intended for installation in cylinders in a sealed 

unvented heating or DHW heating system.
This appliance is designed for domestic use. It can be used safely 

by untrained persons. The appliance can also be used in a non-

domestic environment, e.g. in a small business, as long as it is 

used in the same way.
Any other use beyond that described shall be deemed inappropri-

ate. Observation of these instructions and of instructions for any 

accessories used is also part of the correct use of this appliance.
Using the appliance for heating fluids other than water or water 

supplemented with chemicals, such as brine, is also deemed in-

appropriate.

2.2  General safety instructions

 

WARNING Electrocution

Never spray the appliance with water or other liquids.

 

WARNING Burns

There is a risk of scalding at outlet temperatures in ex-

cess of 43 °C.

!

 

WARNING Injury

The appliance may be used by children aged 8 and up 

and persons with reduced physical, sensory or mental 

capabilities or a lack of experience provided that they 

are supervised or they have been instructed on how to 

use the appliance safely and have understood the result-

ing risks. Children must never play with the appliance. 

Children must never clean the appliance or perform user 

maintenance unless they are supervised.

!

 

Material losses

Condensate can drip from the appliance.

f

f

Never store objects below the appliance.

 

Note

The appliance is under pressure.

During the heat-up process, expansion water will drip 

from the safety valve.

f

f

If water continues to drip when heating is complet-

ed, please inform your heating contractor.

2.3  CE designation

The CE designation shows that the appliance meets all essential 

requirements according to the:

 

- Electromagnetic Compatibility Directive

 

- Low Voltage Directive

2.4  Test symbols

See type plate on the appliance.

3.  Appliance description

The appliance electrically heats DHW and heating water.The 

temperature of the water is set by a qualified contractor via the 

temperature selector. Once the selected temperature has been 

reached, the appliance switches off and restarts automatically 

when required.
The appliance is also protected against frost on the temperature 

setting "cold" as long as the power supply is guaranteed. The 

appliance switches on in good time and heats the water. The tap 

and the mains water supply line are not protected against frost 

by the appliance.

!

Содержание FCR 28/120 Si

Страница 1: ...OPERATION AND INSTALLATION UTILISATION ET INSTALLATION BEDIENING EN INSTALLATIE Heizflansch Flanged immersion heater Corps de chauffe Verwarmingsflens FCR 28 120 Si FCR 28 180 Si FCR 28 270 Si FCR 28...

Страница 2: ...the heating elements and protective pipe 17 14 Specification 18 14 1 Dimensions immersion depths and connections 18 14 2 Wiring diagrams and connections 18 14 3 Data table 20 GUARANTEE ENVIRONMENT AN...

Страница 3: ...emperatures in ex cess of 43 C WARNING Injury The appliance may be used by children aged 8 and up and persons with reduced physical sensory or mental capabilities or a lack of experience provided that...

Страница 4: ...ommercially available des caling agents f f Regularly activate the safety valve to prevent it from becom ing blocked e g by limescale deposits 6 Troubleshooting Fault Cause Remedy The water does not h...

Страница 5: ...ge pipe of the safety valve with a constant downward slope and in a room free from the risk of frost f f The safety valve discharge aperture must remain open to the atmosphere 8 Appliance description...

Страница 6: ...immersion heater The contactors must be switched inde pendently of one another by the thermostats and the high limit safety cut out respectively see chapter Specifica tion Wiring diagrams and connect...

Страница 7: ...high limit safety cut out has responded because the controller is faulty Replace the thermostat and press the high limit safety cut out reset button The high limit safety cut out has responded because...

Страница 8: ...cables PG 13 5 2 Entry electrical cables PG 21 Mating flange 245 219 205 83 14 280 26_02_79_0013 14 2 Wiring diagrams and connections FCR 28 120 Si part number 075140 FCR 28 180 Si part number 075131...

Страница 9: ...6 5 4 L3 L2 L1 4 5 3 1 2 85_02_79_0002 1 Heating element 9 kW connected load 9 x 1 kW 18 kW connected load 9 x 2 kW 27 kW connected load 9 x 3 kW 36 kW connected load 9 x 4 kW 2 Thermostat 3 High limi...

Страница 10: ...00 300 300 Versions IP rating IP24 IP24 IP24 IP24 IP24 IP24 Dimensions External flange diameter mm 280 280 280 280 280 280 Immersion depth mm 325 325 325 450 450 450 Torque Nm 80 80 80 80 80 80 Weight...

Страница 11: ...Y Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26...

Отзывы: