STIEBEL ELTRON FCR 28/120 Si Скачать руководство пользователя страница 4

OPERATION 

 

Settings

14

 | FCR 28 Si www.stiebel-eltron.com

4.  Settings

The temperature can be freely selected by the qualified contractor 

(see chapter "Installation / Settings").
Factory setting: 60 °C

5.  Cleaning, care and maintenance

f

f

Have the electrical safety of the appliance regularly checked 

by an electrician.

Scaling

f

f

Almost every type of water will deposit lime at high tempera-

tures. Limescale will settle inside the appliance and affect its 

function and service life. The heating elements must there-

fore be descaled from time to time. A qualified contractor 

who is aware of the local water quality will tell you when the 

next service is due.

f

f

Check the taps/valves regularly. You can remove limescale 

deposits at the tap outlets using commercially available des-

caling agents.

f

f

Regularly activate the safety valve to prevent it from becom-

ing blocked e.g. by limescale deposits.

6.  Troubleshooting

Fault

Cause

Remedy

The water does not heat 

up.

There is no power. 

Check the fuses/MCBs in 

your fuse box.

 

The temperature is incor-

rectly adjusted.

Check the temperature 

setting.

The flow rate is low. 

 

The aerator in the taps or 

shower heads is dirty or 

scaled-up.

Clean or descale the 

aerator or shower head. 

Water drips from the 

safety assembly after 

heating has stopped. 

 

The valve seat is con-

taminated. 

 

 

Depressurise and isolate 

the appliance from the 

power supply. Request 

your qualified contractor 

to attend.

If you cannot remedy the fault, notify your heating contractor. To 

facilitate and speed up your enquiry, please provide the serial 

number from the type plate (no. 000000-0000-000000):

FCR

Nr.:  000000 - 0000 - 000000

Made in Germany

FCR

Nr.:  000000 - 0000 - 000000

Made in Germany

26

�0

2�

79

�0

07

6

Содержание FCR 28/120 Si

Страница 1: ...OPERATION AND INSTALLATION UTILISATION ET INSTALLATION BEDIENING EN INSTALLATIE Heizflansch Flanged immersion heater Corps de chauffe Verwarmingsflens FCR 28 120 Si FCR 28 180 Si FCR 28 270 Si FCR 28...

Страница 2: ...the heating elements and protective pipe 17 14 Specification 18 14 1 Dimensions immersion depths and connections 18 14 2 Wiring diagrams and connections 18 14 3 Data table 20 GUARANTEE ENVIRONMENT AN...

Страница 3: ...emperatures in ex cess of 43 C WARNING Injury The appliance may be used by children aged 8 and up and persons with reduced physical sensory or mental capabilities or a lack of experience provided that...

Страница 4: ...ommercially available des caling agents f f Regularly activate the safety valve to prevent it from becom ing blocked e g by limescale deposits 6 Troubleshooting Fault Cause Remedy The water does not h...

Страница 5: ...ge pipe of the safety valve with a constant downward slope and in a room free from the risk of frost f f The safety valve discharge aperture must remain open to the atmosphere 8 Appliance description...

Страница 6: ...immersion heater The contactors must be switched inde pendently of one another by the thermostats and the high limit safety cut out respectively see chapter Specifica tion Wiring diagrams and connect...

Страница 7: ...high limit safety cut out has responded because the controller is faulty Replace the thermostat and press the high limit safety cut out reset button The high limit safety cut out has responded because...

Страница 8: ...cables PG 13 5 2 Entry electrical cables PG 21 Mating flange 245 219 205 83 14 280 26_02_79_0013 14 2 Wiring diagrams and connections FCR 28 120 Si part number 075140 FCR 28 180 Si part number 075131...

Страница 9: ...6 5 4 L3 L2 L1 4 5 3 1 2 85_02_79_0002 1 Heating element 9 kW connected load 9 x 1 kW 18 kW connected load 9 x 2 kW 27 kW connected load 9 x 3 kW 36 kW connected load 9 x 4 kW 2 Thermostat 3 High limi...

Страница 10: ...00 300 300 Versions IP rating IP24 IP24 IP24 IP24 IP24 IP24 Dimensions External flange diameter mm 280 280 280 280 280 280 Immersion depth mm 325 325 325 450 450 450 Torque Nm 80 80 80 80 80 80 Weight...

Страница 11: ...Y Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26...

Отзывы: