background image

EN

GL

ISH

www.stiebel-eltron.com 

DEL AU| 

11

INSTALLATION 

 

Installation

f

f

When installing connection pipes that are not offset, break 

off the tabs on the cover guides.

f

f

Click the cover guides into place in the pipe apertures.

f

f

Position the back panel guides on the extensions. Push them 

together. Then push the guides until they are resting against 

the back panel.

10.3  Installation options

 

- Electrical connection from above on unfinished walls

 

- Electrical connection for finished walls

 

- Large cross-section for electrical connection from below

 

- Water installation on unfinished walls

 

- Wall mounting bracket when replacing an appliance

 

- Installation with offset tiles

 

- Pivoting appliance cover 

 

- Operation with preheated water

 

- Anti-scalding protection / temperature limit

Electrical connection from above on unfinished walls

26

�02

�02

�1

12

3�

f

f

Cut open the cable grommet for the power cable.

f

f

Push down the locking hook to secure the mains terminal. 

Pull out the mains terminal.

f

f

Reposition the mains terminal in the appliance from the 

bottom to the top and secure the mains terminal by sliding it 

under the locking hook.

f

f

Lay the control wires below the wire guide.

Power cable for finished walls

!

 

Material losses

If you cut open the wrong knock-out in the appliance 

cover by mistake, you must use a new appliance cover.

f

f

Cut or break out the required entries in the back panel and 

appliance cover cleanly (for positions, see chapter "Specifica-

tion / Dimensions and connections"). If necessary, use a file.

f

f

Route the power cable through the cable grommet. Connect 

the power cable to the mains terminal.

 

Note

This type of connection changes the protection rating of 

the appliance.

f

f

Change the type plate. Cross out "IP 25" and mark 

the box "IP 24". Please use a ballpoint pen to do this.

Large cross-section for electrical connection from below

If you use cables with a large cross-section, you can fit the cable 

grommet after the appliance has been installed.

1.

3.

4.

2.

26

�02

�02

�1

12

4�

f

f

Before installing the appliance, use a screwdriver to push out 

the cable grommet.

f

f

Slide the cable grommet over the power cable. For this, use 

the installation aid. If the cross-section is > 6 mm², enlarge 

the hole in the cable grommet. 

f

f

Push the cable grommet into the back panel.

Water installation on unfinished walls

26

�0

2�

02

�0

79

8

f

f

Seal and screw in the twin connectors (not included in stand-

ard delivery).

D

00000

41

72

4

2

3

1

3

1  Tee for cold water

2  Tee for domestic hot water

3  Cover

f

f

Fit the water connections.

Содержание DEL 18 AU

Страница 1: ...OPERATION AND INSTALLATION Electronically controlled instantaneous water heater DEL 18 AU DEL 27 AU M1 Tmax M2...

Страница 2: ...13 1 Service mode 14 13 2 Indicator options for LED diagnostic traffic light 15 13 3 Fault table 15 14 Maintenance 16 15 Specification 16 15 1 Dimensions and connections 16 15 2 Wiring diagram 17 15 3...

Страница 3: ...Symbol Type of risk Injury Electrocution Burns or scalding 1 1 3 Keywords KEYWORD Meaning DANGER Failure to observe this information will result in serious injury or death WARNING Failure to observe...

Страница 4: ...and environment Protect the appliance and its tap against frost 2 3 CE designation The CE designation shows that the appliance meets all essential requirements according to the Low Voltage Directive E...

Страница 5: ...d temperature The temperature is confirmed with 1x flashing Note If the outlet temperature is not sufficiently high when the draw off valve is fully open and the temperature selector is set to maximum...

Страница 6: ...the appliance f f Check the taps regularly Limescale deposits at the spouts can be removed using commercially available descaling agents 6 Troubleshooting Fault Cause Remedy The appliance will not sta...

Страница 7: ...al resistance of the water see chapter Specification Application areas Your water supply utility will advise you of the specific electrical water resistance or conductivity 8 Appliance description 8 1...

Страница 8: ...on for installation on finished walls For the appliance with adjustable connected load the middle load is preset For further installation options see chapter Installation options electr o nic comfor t...

Страница 9: ...in the case of water preheated by solar energy When using the appliance for showering f f With low water pressure The pressure drop can be reduced by replacing the flow limiter with the plastic profil...

Страница 10: ...n Wiring diagram The specified voltage must match the mains voltage Lower back panel installation 1 2 26_02_02_1080 1 Connection pieces delivered in the pack 2 Screw f f Cut open the lower part of the...

Страница 11: ...ow the wire guide Power cable for finished walls Material losses If you cut open the wrong knock out in the appliance cover by mistake you must use a new appliance cover f f Cut or break out the requi...

Страница 12: ...If necessary use a screwdriver DHF replacement 26_02_02_0815_ f f Remove the DHF wall mounting bracket f f Take the new wall mounting bracket and move the thread ed stud to the position marked with DH...

Страница 13: ...Initial start up elect ronic com for t D0000040746 f f Open and close all connected draw off valves several times until all air has been vented from the pipework and the appliance f f Check for leaks...

Страница 14: ...order to check the appliance it must be connected to the power supply 13 1 Service mode M1 Tmax M2 D0000040982 1 2 1 Memory keys M1 and M2 2 Spanner symbol The spanner symbol is displayed in the event...

Страница 15: ...high limit safety cut out has responded or its lead is broken Check the appliance and the high limit safety cut out The set temperature is not achieved One phase down Check the fuses MCBs in your fuse...

Страница 16: ...rainer A strainer is located in the tee from the cold water inlet pipe In case of contamination you can remove this strainer and clean it D0000041722 1 3 2 1 Flow limiter or 2 Plastic profile washer 3...

Страница 17: ...10 1 3 2 3 6 4 1 4 8 11 0 3 5 3 9 4 5 5 2 12 0 3 8 4 3 4 9 5 7 12 2 3 9 4 4 5 0 5 8 13 2 4 2 4 7 5 4 6 3 13 5 4 3 4 8 5 5 6 4 13 6 4 3 4 9 5 6 6 5 14 2 4 5 5 1 5 8 6 8 14 5 4 6 5 2 5 9 6 9 15 0 4 8 5...

Страница 18: ...Max mains impedance at 380V 60Hz 0 392 Max mains impedance at 400V 60Hz 0 372 Connections Water connection G 1 2 A G 1 2 A Application limits Max permissible pressure MPa 1 0 1 0 Max inlet temperatur...

Страница 19: ...oses means that the unit is used in a domestic dwelling Component Warranty period All components 5 years from the date of completion of the installa tion of the unit 7 The warranty period for a unit u...

Страница 20: ...etres from our closest authorised ser vice technician 13 2 for the extra time it takes our authorised service technician to access the unit for inspection and testing if it is not sited in accordance...

Страница 21: ...ENGLISH www stiebel eltron com DEL AU 21 NOTES...

Страница 22: ...22 DEL AU www stiebel eltron com NOTES...

Страница 23: ...ENGLISH www stiebel eltron com DEL AU 23 NOTES...

Страница 24: ...eltron dk www stiebel eltron dk Finland STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 8...

Отзывы: