InStallatIon
Product description
3. Product description
3.1 standard delivery
the brine charging unit is delivered with the following:
-
Safety valve
-
hook wrench
4. Installation
Install the brine charging unit into the heat source system for
a brine | water heat pump.
f
f
observe the flow direction (see chapter "Specification /
Dimensions and connections").
!
Material losses
Mount the brine charging unit horizontally aligned
and free of stress.
4.1 charging the heat source system
1
2
3
4
D
00000
384
22
5
1 Shut-off valve, heat pump flow
2 Filling
3 Drain
4 Shut-off valve, heat source flow
5 Quick-action air vent valve
f
f
Close the shut-off valve in the heat source flow.
f
f
open the shut-off valve in the heat pump flow.
f
f
Connect the refrigerant flow line to the charging side of
the unit.
f
f
Connect the refrigerant return line to the draining side of
the unit.
f
f
Carry out a pressure test. For this, remove the safety valve
and insert the plug supplied.
1.
3.
4.
2.
D
00000
38
15
7
1
2
1 Safety valve
2 Plug
f
f
Check for tightness.
f
f
Charge the heat source system to the required operating
pressure. For this, observe the maximum operating pres-
sure (see chapter "Specification / Data table").
f
f
Close the shut-off valve in the heat pump flow.
f
f
Remove the plug and refit the safety valve.
f
f
Vent the heat source system.
f
f
after venting, close the quick-action air vent valve.
4.2 removing the strainer
If there is a high pressure drop into the heat source system you
can remove the strainer in the filter chamber of the brine charg-
ing unit (see chapter "Specification / Pressure drop diagram").
!
Material losses
For opening and closing the filter chamber, use exclu-
sively the hook wrench supplied.
Max
15 Nm
1
26
�0
3�
01
�1
92
2
2
1 Strainer
2 Filter cartridge
f
f
open the filter chamber. Remove the filter cartridge.
f
f
Remove the strainer from the heat pump flow.
f
f
Re-insert the filter cartridge. Close the filter chamber.
f
f
tighten the cover with a torque of 15 nm.
f
f
open the shut-off valves in the heat source flow and the
heat pump flow.
f
f
Vent the heat source system.
f
f
after venting, close the quick-action air vent valve.
5. maintenance
Clean the filter cartridge if required.